1 General

1.13 BSI Certification

This appliance is certificated to the current issue of BS6332
Part 1 invoking the current issue of BS5258 Part 8 for safety
and performance. It is, therefore, important that no alteration
is made to it without permission, in writing, from Hepworth
Heating Ltd.

Any alteration that is not approved by Hepworth Heating Ltd.,
could invalidate the BSI Certification of the boiler, warranty and
could infringe the current issue of the Statutory Requirements.

CE Mark

The CE mark on this appliance shows compliance with:

1. Directive 90/396/EEC on the approximation of the Laws of
the Member States relating to appliances burning gaseous
fuels.

2. Directive 73/23/EEC on the harmonization of the Laws of
the Member States relating to electrical equipment designed
for use within certain voltage limits.

3. Directive 89/336/EEC on the approximation of the Laws of
the Member States relating to electromagnetic compatibility.

This boiler meets the requirements of Statutory Instrument,
No. 3083, The Boiler (Efficiency) Regulations, and therefore is
deemed to meet the requirements of Directive 92/42/EEC on
the efficiency requirements for new hot water boilers fired with
liquid or gaseous fuels.

Type test for purposes for Regulation 5 certified by: Notified
body 0086.

Product/production certified by: Notified body 0086.

1.14 Inhibitor

Attention is drawn to the current issue of BS5499 and BS7593
on the use of inhibitors in central heating systems.

If an inhibitor is to be used, contact a manufacturer for their
recommendations as to the best product to use.

If using in an existing system take special care to drain the
entire system, including the radiators, then thoroughly cleaning
out before fitting the boiler whether or not adding an inhibitor.

Diagram 1.4

6242

BOILER

22mm
CENTRAL
HEATING
RETURN

28mm

DISTRIBUTOR
TUBE IN RETURN
CONNECTION

22mm
CENTRAL
HEATING
FLOW

FLOW

RETURN

INDIRECT

CYLINDER

27 METRES

MAXIMUM

IMPORTANT
DIMENSION
NOT LESS
THAN 145mm

C

L

PUMPED HEATING &
GRAVITY DOMESTIC HOT
WATER (DIAGRAMMATIC)

* CORNER IN-FILL
(not required to be
full depth of opening)

FULLY PUMPED SYSTEM
(DIAGRAMMATIC)

Diagram 1.5

The COLD FEED PIPE may be connected to the flow
pipe, adjacent to the open vent pipe as shown .
(THERE MUST ALWAYS BE A COLD WATER PATH
TO THE RETURN CONNECTION Of THE BOILER.)

C

L

BOILER

22mm MIN
OPEN VENT

INDIRECT
CYLINDER

MANUAL
AIR VENT

15mm
COLD
FEED

PUMP

HEATING
CIRCUIT

150mm MAX

7218

1 metre MIN
27 metres MAX

405 mm. MIN.

Diagram 1.3

6408

FRONT
OPENING