8 servicing – Glow-worm 56/3e Back Boiler User Manual

Page 22

Advertising
background image

22

221725B

Diagram 8.5

6886

GAS
CONTROL
VALVE

PILOT TUBE NUT

GAS
MANIFOLD

SECURING
SCREWS

THERMOCOUPLE
NUT

8 Servicing

8.5 Lint Arrester

Remove the four securing screws to disengage the two lint
arresters, see diagram 8.6.

Clean the lint arresters as required.

8.6 Main Burner - Injector

Inspect the main burner injector for damage or blockage, clean
or replace as necessary. If replacing ensure the new copper
washer is fitted, see diagram 8.7.

Do not use a wire or sharp instrument to clean the injector hole.

8.7 Flue Blockage Safety Device Assembly

Gain access as relevant part of Section 8.3. Remove any dust
and lint, inspect the pilot for damage. Remove the sensing tube
adapter, to clean, blow through, do not use a wire or sharp
instrument. Inspect the electrode and thermocouple for wear
or damage, clean, or replace as necessary the flue blockage
safety device, see diagram 8.8.

To remove the safety device, disconnect the pilot tube nut and
two securing screws, see diagram 8.9.

Ensure the electrode is in line with the earth post and the spark
gap is as shown in diagram 8.8.

Note: When reassembling the burner assembly the following
points should be observed:

a) Make sure that the lint arresters are engaged in the correct
position on the burner support bracket.

b) DO NOT replace the combustion chamber control/burner
assembly into the back boiler until the boiler flueways servicing
has been carried out.

Diagram 8.6

6191

LINT ARRESTER

SECURING SCREW (4)

Advertising