221807B

CAPILLARY REMOVAL

Diagram 9.7

CAPILLARY

CABLE CLIPS(2)

ELECTRICAL CONNECTIONS

Diagram 9.6

FLUE
BLOCKAGE
SAFETY
DEVICE

0904/A

5041

ELECTRICAL
CONNECTIONS

SECURING
LOCKNUT

CAPILLARY

FLUE
BLOCKAGE
SAFETY
DEVICE

9 Replacement of Parts

INSULATION PANELS

Diagram 9.5

SIDE
INSULATION
PANEL

REAR
INSULATION
PANEL

1670

GRAPHITE
COATED
NUT

SCREW

CLIP

BAFFLE
TRAY

9.7 Pilot Burner

Follow the instructions in the relevant parts of Section 8.1 to
remove cover and burner controls assembly.

Remove the lint arrester as in Section 8.2.

Disconnect the thermocouple nut at the pilot burner, see diagram
9.3.

Disconnect the nut retaining the pilot tube and injector in the
pilot burner.

Remove the two screws and nuts securing the pilot burner and
the shield front cover, see diagram 9.3.

Check that the pilot flame length is as shown in diagram 7.3.

Replace thermostat phial as Section 8.1.

Replace lint arrester as Section 8.2.

9.8 Insulation Panels

Follow the relevant instructions in Section 8.1.

Unfasten the two screws retaining each side insulation panel
within the combustion chamber and remove panel, see diagram
9.5.

Release the rear insulation panel upper clips and lift out panel.

Replace thermostat phial as Section 8.1.

9.9 Injector

When the burner has been removed from the injector manifold
as in Section 8.2 the injector can be unscrewed from the
manifold and renewed as necessary.

When replacing use a little jointing compound on the external
threads only, to make a gas tight seal.

Replace thermostat phial as Section 8.1.