Instructions for use – Glow-worm Hideaway 40CF User Manual

Page 4

Advertising
background image

4

221807B

To Light the Boiler

WARNING. If the pilot light goes out for any reason, do not
attempt to relight until three minutes have gone by.

Remove the door by pulling forwards with the fascia at the top.
Lift up to free from bottom side lugs.

Refer to diagram 1 to identify the controls.

Check that the mains electrical supply to the boiler is switched
OFF.

Check that the Flue Blockage Safety Device has not operated,
that is, the button is in. Refer to Safety Device instructions.

Push in slightly and turn gas control knob “A” clockwise until
'

'is against its setting point.

Turn thermostat control knob “B” anticlockwise until “O” is
against its setting point.

Push in slightly and turn gas control knob “A” anticlockwise until
'

' is against its setting point, then push fully and hold in.

Push and release piezo ignition button “C” until the pilot burner
lights.

Air may be present in the supply pipe so the lighting of the pilot
may need to be repeated until all the air has been expelled.

When the pilot is alight, view through window “E”, keep gas
control knob “A” fully pushed in for about 15 seconds, then
release.

If the burner fails to stay alight, wait three minutes, then repeat
the lighting procedure only now keep control knob “A” depressed
for a little longer before releasing. The Flue Blockage Safety
Device may also need resetting, refer to instructions above.

If the gas control knob “A” is turned to '

', a safety lock

prevents it being turned on again for a short period. No attempt
should be made to relight the pilot for at least three minutes.

Make sure that the pilot is alight and stable, then switch on the
electrical supply.

Press in and turn gas control knob “A” anticlockwise until '

'

is against its setting point.

Set any remote controls to call for heat.

Turn the boiler thermostat knob “B” clockwise until “MAX” is
against its setting point and the main burner will light. Adjust
thermostat to required setting between “MIN” and “MAX”.
“MAX” is about 82

o

C (180

o

F).

Refit the door by fitting the hooked runner at the bottom into the
slot in the side panels and pushing onto the studs.

To Turn the Boiler Off

For short periods. Turn the boiler thermostat control knob “B”
anticlockwise to “O”. The pilot will remain alight. To relight the
main burner turn the thermostat control knob “B” clockwise to
the desired setting between “MIN” and “MAX”.

For longer periods. Push in slightly and turn gas control knob
“A” fully clockwise until “

” is against its setting point. Turn

thermostat control knob “B” anticlockwise to “O”. Isolate the
boiler from the electrical supply. Follow the full lighting procedure
to relight.

Refer also to “Protection Against Freezing”.

Gas Leak or Fault

If a gas leak or fault exists or is suspected the boiler must be
turned off, including the electrical supply and must not be used
until the fault has been put right. Advice/help should be obtained
from the local gas undertaking or your installation/servicing
company.

Protection Against Freezing

If the boiler is to be out of use for any long period of time during
severe weather conditions we recommend that the whole of the
system including the boiler, be drained off to avoid the risk of
freezing up. If an immersion heater is fitted in the domestic hot
water cylinder make sure it is switched off.

Sheet Metal Parts

WARNING. This appliance contains metal parts (component)
and care should be taken when handling and cleaning, with
particular regard to edges.

Cleaning

Keep the casing clean by wiping it over occasionally with a
damp soapy cloth and dry with a polishing cloth.

Do not use abrasive cleaners.

Replacement Parts/Boiler Identification

If replacement parts are required apply to your local supplier or
gas undertaking. Please quote the name of the boiler and its
serial number which can be found on the data label positioned
on the boiler top, to the rear of the inclined flueway cleaning
door.

Clearance

Minimum clearances must be left around the boiler as shown in
diagram 1.2 and 1.3.