Instructions for use – Glow-worm Hideaway 40CF User Manual

Page 3

Advertising
background image

3

221807B

Warning

Make sure that nothing obstructs the rear side grilles or
clearances. See diagram 1.2 and 1.3 for minimum clearances.

Boilers Installed in a Compartment

If the boiler is fitted in a compartment, cupboard etc., do not
obstruct the purpose built compartment vents or grille on the
boiler.

Do not use the compartment for storage purposes.

Maintenance

To ensure the continued efficient and safe operation of the
boiler it is recommended that it is checked and serviced at
regular intervals. The frequency of servicing will depend upon
the particular installation conditions and usage, but in general
once a year should be enough.

If this appliance is installed in a rented property there is a duty
of care imposed on the owner of the property by the current
issue of the Gas Safety (Installation and Use) Regulations,
Section 35.

It is the law that servicing is carried out by a competent person.

To obtain service please call your installer or Heatcall (Glow-
worm’s own service organisation) using the telephone number
given on the inside of the front panel.

Please be advised that the ‘Benchmark’ logbook should be
completed by the installation engineer on completion of
commissioning and servicing.

All CORGI Registered Installers carry a CORGI ID card, and
have a registration number. Both should be recorded in your
boiler Logbook. You can check your installer is CORGI registered
by calling CORGI direct on :- 01256 372300.

Boiler Electrical Supply

WARNING. This boiler must be earthed.

The boiler must only be connected to a 240V~50Hz supply,
protected by a 3A fuse, maximum.

All wiring must be in accordance with the current issue of
BS7671.

Heat resistant cable having a conductor size of 0.75mm

2

, (24/

0.22mm), to BS6500 Table 16 must be used.

To Connect an Electrical Plug

The colours of three core flexible cable are, Brown - live, Blue
- neutral, Green and yellow - earth.

As the markings on your plug may not correspond with these
colours continue as follows:

The wire coloured brown must be connected to the terminal
marked “L” or Red.

The wire coloured blue must be connected to the terminal
marked “N” or Black.

The wire coloured green and yellow must be connected to the
terminal marked “E”, Green or the earth symbol

.

SETTING
POINTS

FLUE
BLOCKAGE
SAFETY
DEVICE
RESET
BUTTON

40 OPEN FLUE

SETTING
POINT

GAS CONTROL
KNOB 'A'

THERMOSTAT
CONTROL
KNOB 'B'

E

0938

PIEZO
IGNITION
BUTTON
'C'

Diagram 1

Instructions for Use

GAS CONTROL KNOB

= OFF

= PILOT/IGNITION

= MAIN BURNER

Safety Device

This appliance is fitted with a flue blockage safety device which
will shut down the appliance in the event of abnormal flue
conditions. This device is NOT a substitute for an independently
mounted Carbon Monoxide detector.

The safety device is reset, after three minutes, by pushing in the
button shown in diagram 1.

Shut down can occur during certain climate conditions, but if it
recurs the chimney flue and air inlet into the room must be
checked and any problems found corrected by a competent
person, before the boiler is used again.