11 electrical connection – Glow-worm Ultracom cx User Manual

Page 36

Advertising
background image

36

WARNING:

This appliance must be earthed.

● This appliance must be wired in accordance with these

instructions. Any fault arising from incorrect wiring cannot be

put right under the terms of the Glow-worm guarantee.

● All system components must be of an approved type.

Electrical components have been tested to meet the equivalent

requirements of the BEAB.

● Do not interrupt the mains supply with a time switch or

programmer.

● Connection of the whole electrical system and any heating

system controls to the electrical supply must be through a

common isolator.

● Isolation should preferably be by a double pole switched

fused spur box having a minimum contact separation of 3mm

on each pole. The fused spur box should be readily accessible

and preferably adjacent to the boiler. It should be identified as

to its use.

● A fused three pin plug and shuttered socket outlet may be

used instead of a fused spur box provided that it is not used in a

room containing a fixed bath or shower.

● The boiler is suitable for installation in bathroom zones 2 and

3

11.1 Electrical Wiring

Remove the electrical cartridge from the fittings pack.
Remove the securing screw to open the cartridge, see diagram

11.1.
NOTE: There are two screws supplied loose in the electrical

cartridge, these will be required to secure the cartridge into the

electrical interface housing.
Slacken the screws of the cable strain relief in the electrical

cartridge, see diagram 11.1.
Route the mains supply and system cables through the strain

relief and connect to the relevant plug, refer to the appropriate

sections 11.2 or 11.3 .

13302

Diagram 11.1

11 Electrical Connection

Diagram 11.3

13369

Diagram 11.2

13368

Advertising