13 Servicing

13555

Diagram 13.7

13272

Diagram 13.8

13.4. Combustion Chamber and Heat

Exchanger

Remove loose debris from inside the combustion chamber

using a soft brush and vacuum cleaner.

Carefully flush by spraying water into the heat exchanger, any

remaining debris should pass through the condensate trap

(Ensure the water is kept away from electrical components).

13.5 Inner Casing Panel Seal check

Check the condition of the seal, if worn or damaged remove

the seal and thoroughly clean the casing surface before fitting

the new seal, see diagram 13.8.

Refit the inner casing panel.

NOTE: Ensure the seal is fitted correctly giving an airtight

joint.

13.6 Service Completion

Re-check the combustion as described at the beginning of

this section.

On completion of the service the “Benchmark” Service Record

should be completed.
NOTE: If the burner is not to be serviced, do not perform the

following instructions 13.5, 13.6, 13.7 and 13.8 but continue to

section 13.9 to complete the servicing.