13 servicing – Glow-worm Ultracom sxi User Manual

Page 44

Advertising
background image

44

13 Servicing

13527

13.4 Combustion Chamber and Heat

Exchanger

Remove loose debris from inside the heat exchanger using a

soft brush and vacuum cleaner.
Carefully flush by spraying water into the heat exchanger, any

remaining debris should pass through the condensate trap

(Ensure the water is kept away from electrical components).

13.5 Inner Casing Panel Seal check

Check the condition of the seal, if worn or damaged remove

the seal and thoroughly clean the casing surface before fitting

the new seal, see diagram 13.8.
Refit the inner casing panel.
NOTE: Ensure the seal is fitted correctly giving an airtight

joint.

13.6 Service Completion

Re-check the combustion as described at the beginning of this

section.
On completion of the service the “Benchmark” Service Record

should be completed.

Diagram 13.7

10063

Diagram 13.8

Advertising