1 boiler specification, Boiler specification 18sxi 30sxi – Glow-worm Ultracom sxi User Manual

Page 7

Advertising
background image

7

1 Boiler Specification

13498

Table 1. Flow Rate

MODEL MINIMUM FLOW RATE
18sxi

774 litres/hr.

30sxi

1289 litres/hr.

This is equal to 20

o

C differential at maximum heat input.

BOILER SPECIFICATION

18sxi

30sxi

Lift weight

36kg (80Ib)

39kg (86Ib)

Total weight (installed)

41kg (90Ib)

44.5kg (98Ib)

Gas connection

15mm copper

15mm copper

Heating flow & return connection Ø O.D.

22mm. copper

22mm. copper

Condensate connection Ø I.D.

21.5mm. plastic

21.5mm. plastic

Safety valve

3 bar (43/5Ibf/in

2

)

3 bar (43/5Ibf/in

2

)

Safety valve discharge

15mm. copper

15mm. copper

Expansion vessel capacity

8 litres (1.76 gallons)

8 litres (1.76 gallons)

Expansion vessel charge pressure

0.5bar (7,3Ibf/in

2

)

0.5bar (7,3Ibf/in

2

)

Electrical supply

230V~50Hz fused 3A

230V~50Hz fused 3A

Electrical rating

180W fused 3A

180W fused 3A

EN60529 IP clasification

IPX4D

IPX4D

Internal fuse rating on main PCB

2A

2A

Gas supply (governed meter only)

II

2H3P

G20 natural gas

II

2H3P

G20 natural gas

Inlet gas working pressure

20mbar

20mbar

Burner % CO

2

case on

9.3 nominal

9.3 nominal

Burner % CO

2

case off

9.1 nominal

9.1 nominal

2.0 m

3

/h

3.0 m

3

/h

71 ft

3

/h

107 ft

3

/h

0.53 m

3

/h

0.53 m

3

/h

18.7 ft

3

/h

18.7 ft

3

/h

Flue type

C

13

, C

33

, C

43

, C

53

C

13

, C

33

, C

43

, C

53

NOx

Class 5

Class 5

Heat output condensing mode

20.02kW

30.58kW

Heat input Nett Q = kW

max. 18.9 min. 5

max. 28.6 min. 5.3

Heat output P = kW

max. 18.57 min. 4.95

max. 28.17 min. 5.25

SEDBUK rating

Band A 90.4%

Band A 90.6%

Approximate max. gas rate

after 10 mins. from cold

Approximate min. gas rate

after 10 mins. from cold

Advertising