15 Replacement of Parts

15.20 Low Water Pressure Sensor

For access, refer to section 15.1.
Drain the boiler heating circuit as described in the appropriate

section of 15.1.
Refer to diagram 15.15.
Disconnect the electrical leads.
Remove the retaining clip, remove the low water pressure

sensor.
Fit new ‘O’ ring.
Fit the new low water pressure sensor.
Refill vent and pressurise the boiler.

15.21 Automatic Bypass and Housing

For access, refer to section 15.1.
Drain the boiler heating circuit as described in the appropriate

section of 15.1.
Refer to diagram 15.16.
Remove the retaining clip to remove the automatic bypass.
Remove the retaining clips and three securing screws to

remove the automatic bypass housing. Fit new ‘O’ rings

before replacing the assembly.
Refill, vent and pressurise the boiler.

RETAINING

CLIP

LOW WATER

PRESSURE

SENSOR

ELECTRICAL

LEADS

LH

HYDROBLOCK

Diagram 15.15

13532

13854

Diagram 15.16

13526

PUMP

HEAD

CABLE

COVER

AUTOMATIC

AIR VENT

RETAINING

CLIP

MAINTENANCE

COVER

Diagram 15.14

RETAINING

CLIP

SECURING

SCREW (3)

RETAINING

CLIP

AUTOMATIC BYPASS

HOUSING