12 Servicing
12.6 Condense Trap and Siphonic Drain
The condensate trap & siphonic drain does not normally need
servicing unless material deposits exceed beyond the service
fill level, see diagram 12.14.
To clean the condense trap remove the sump and rinse with
water.
13356
BURNER
FRONT INSULATION
GASKET
SECURING
SCREW (4)
SPARK
ELECTRODE
GAS VALVE
AND FAN
BURNER
DOOR
Diagram 12.12
Diagram 12.13
15452
GAS CONTROL
VALVE
OFFSET
ADJUSTMENT
THROTTLE
ADJUSTER
Diagram 12.15
13762
SEAL (4 pieces)
BOILER MODULE
FRONT CASING
PANEL
FLEXIBLE
CONDENSATE
HOSE
CONDENSE TRAP
& SIPHONIC DRAIN
Turn
anti-clockwise
to remove
SERVICE
FILL LEVEL
Diagram 12.14
13326
12.7 Boiler Module Front Casing Panel Seal
Check
Check the condition of the seal, if worn or damaged remove
the seal and thoroughly clean the casing surface before fitting
the new seal, see diagram 12.15.
Refit the casing panel.
NOTE: Ensure the seal is fitted correctly giving an airtight
joint.