14 replacement of parts – Glow-worm Ultrapower sxi User Manual

Page 54

Advertising
background image

54

RETAINING

CLIPS

CONTROL

BOX

14.33 Access to Control Box Internals

For access, refer to section 14.1.
Carefully pull the control box forwards so that it lies

horizontally in its hinges.
Do not allow the front of the control box to swing down and be

loosely held by its electrical connections.
Release the four retaining clips, see diagram 14.27, to

remove the rear cover and gain access to the electrical

connections, main PCB and appliance interface PCB.

14.34 Main PCB

For access, refer to section 14.33.
Remove the electrical connections to the PCB.
Ease back the four PCB retaining clips and withdraw the PCB

from the retaining lugs, see diagram 14.28.
When refitting the control box cover ensure the leads do not

become trapped.

14.35 Fuse, Main PCB - Control Box

For access, refer to section 14.33.
The fuse is located at top left hand side of the main PCB, see

diagram 14.28.

14.36 User Interface

Refer to section 14.33 for access.
Remove the main PCB, refer to section 14.34.
Remove the electrical connection.
Gently ease back the retaining clips, see diagram 14.29.
Withdraw the board.
When replacing the board refer to instructions supplied with

replacement PCB.

14.37 Boiler Module Front Casing Panel Seal

Remove the seal and thoroughly clean the casing surface

before fitting the new seal, see diagram 12.15.
Refit the casing panel.
NOTE: Ensure the seal is fitted correctly giving an airtight

joint.

14 Replacement of Parts

Diagram 14.29

MAIN PCB

RETAINING

CLIP (4 OFF)

ELECTRICAL

CONNECTION

RETAINING

LUG (2 OFF)

FUSE

Diagram 14.28

13372

Diagram 14.27

13446

APPLIANCE

INTERFACE

PCB

RETAINING

CLIPS

ELECTRICAL

CONNECTION

13355

Advertising