14 replacement of parts – Glow-worm Ultrapower sxi User Manual

Page 47

Advertising
background image

47

RETAINING

BRACKET

INSIDE VIEW OF

CONTROL BOX

ELECTRICAL

CONNECTION

RETAINING

CLIP

UNION

NUT

PUMP

RETAINING

SCREW

TOP VIEW OF

CENTRAL HEATING PUMP

UNION

NUT

RETURN PIPE

14 Replacement of Parts

CONNECTION

CLIPS

HEATING

RETURN

HEATING

FLOW

HEAT EXCHANGER

Diagram 14.9

13327

Diagram 14.11

13342

Remove the two connection clips securing the flow and return

pipes to the heat exchanger, see diagram 14.9.
Move the pipes away from the heat exchanger.
Remove the four heat exchanger securing screws and

clamps, see diagram 14.8.
CAUTION: There will be water in the heat exchanger.
Remove the push fit condense pipe from the bottom of the

heat exchanger, see diagram 14.10.
Carefully remove the heat exchanger and disconnect the flue

overheat thermostat, see diagram 12.11.

13444

Diagram 14.10

HEAT EXCHANGER CONDENSATE

CONNECTION (push-fit)

Advertising