14 Replacement of Parts

14.31 Immersion Heater

For access, refer to section 14.1.
Refer to section 5.3 and drain the hot water storage tank.
Remove the flexible condensate hose from the condensate

trap and siphonic drain, see diagram 12.14.
Isolate any electrical connections to the immersion heater.
Unscrew the large locknut holding the immersion heater in

place on the hot water tank, see diagram 14.25.
Remove immersion heater and gasket.
When replacing the immersion heater a new gasket is also

supplied.

14.32 Condense Trap & Siphonic Drain

For access, refer to section 14.1.
Remove the flexible condensate hose by pulling out of

condense trap and siphonic drain, see diagram 12.14.
Refer to diagram 14.26.
Remove the securing screw holding the trap/drain.
Remove the float to clean it. When replacing, ensure that the

float is inserted correctly as shown in diagram 14.26.
Flush water through the trap/drain to remove any remaining

solids.
Check for any debris in the outlet pipe of the condense trap

and siphonic drain and clean as necessary.
Reassemble and refit.

Diagram 14.25

IMMERSION

HEATER

13333

Diagram 14.26

13332

SECURING

SCREW

CONDENSE TRAP

& SIPHONIC DRAIN

FLOAT

Advertising