HITEC X2 Ultima: DC/DC, 200 Watt, Dual Port Multi-Charger User Manual

Page 14

Advertising
background image

INC

DEC

INC

INC

DEC

User set up starting screen.

This screen displays the nominal voltage of a Lithium battery. There

are three kinds of Lithium batteries: LiFe(3.3V), Li-Ion(3.6V) or LiPo

(3.7V). It is very important to check the battery carefully and set it up

correctly. If the correct value of the battery is not assigned, an

explosion may occur during the charge process.

The X2 Ultima recognizes the cell count of a Lithium battery

automatically at the beginning of the charge or discharge process

to avoid an erroneous setting by the user. However, a deeply

discharged battery can be incorrectly perceived. To prevent this

error, you can set the time term to verify the cell count by the

processor. Normally, 10 minutes is enough time to perceive the

cell count correctly. For a larger capacity battery, you may extend

the time term. If you set the time term too long for a smaller capacity

EDWWHU\WKHFKDUJHRUGLVFKDUJHSURFHVVFDQEH¿QLVKHGZLWKLQWKH

time term even with an erroneous cell count. This may cause a fatal

result. If the processor recognizes the cell count incorrectly at the

beginning of the charge or discharge process, you may extend the

time. Otherwise, you should use the default value.

The X2 Ultima will be operated with the default value of the essential user settings when

LWLVFRQQHFWHGWRD9EDWWHU\IRUWKH¿UVWWLPH7KHVFUHHQGLVSOD\VWKHIROORZLQJ

information in sequence and the user can change the value of the parameter on each

screen. When you are willing to alter the parameter value in the program, press the

start/enter key to make it blink, then change the value with the Inc> or <Dec key.

The value will be stored by pressing the

start/enter key once.

Initial parameter set up (user’s set up):

INITIAL PARAMETER SET UP (USER’S SET UP)

Termination of NiMH and NiCd battery. The effective value ranges

from 5 ~ 20mV per cell. If the trigger voltage is set higher, there is

a danger of overcharging the battery. If it is set lower, there is a

possibility of premature termination. Please refer to the technical

specification of the battery. (NiCd default: 12mV, NiMH default:

7mV).

INC

DEC

INC

DEC

DEC INC

DEC INC

13