Checking gas connections, Connecting to gas supply, Warning – Desa CGP10R User Manual

Page 14: Caution

Advertising
background image

14

101866

IMPORTANT:

Hold pressure regulator with wrench when connecting it to gas

piping and/or fittings.

Figure 13 - Gas Connection

* An A.G.A. design certified manual shutoff valve with 1/8" NPT tap is an acceptable
alternative to test gauge connection. Purchase the optional A.G.A. design certified
manual shutoff valve from your dealer. See Accessory, page 26.

CHECKING

GAS

CONNECTIONS

PRESSURE TESTING GAS SUPPLY PIPING SYSTEM

Test Pressures In Excess Of 1/2 PSIG

1. Disconnect heater and its individual manual shutoff valve from gas supply

piping system. Pressures in excess of 1/2 psig will damage heater regulator.

2. Cap off open end of gas pipe where manual shutoff valve was connected.

Tee Joint

Reducer
Bushing to
1/8" NPT

1/8" NPT
Plug Tap

Heater
Cabinet

Pressure
Regulator

3/8" NPT
Pipe Nipple

Tee

Joint

Pipe

Nipple

Cap

Ground Joint
Union

From

External

Regulator

(11" W.C. to

14" W.C. Pressure)

Manual Shutoff
Valve *

Sediment Trap

Test

Gauge

Connection *

3" Minimum

WARNING ICON

G 001

WARNING

Test all gas piping and connections for leaks after installation or
servicing. Correct all leaks at once

WARNING ICON

G 001

WARNING

Never use an open flame to check for a leak. Apply a mixture of
liquid soap and water to all joints. Bubbles forming show a leak.
Correct all leaks at once.

WARNING ICON

G 001

CAUTION

Make sure external regulator has been installed between propane/
LP supply and heater. See guidelines under

Connecting to Gas

Supply, page 13.

CONNECTING

TO GAS

SUPPLY

Continued

Advertising