25

101866

Btu (Variable)

5,500/10,000

Type Gas

Propane/LP Only

Ignition

Piezo

Pressure Regulator Setting

8" W.C.

Inlet Gas Pressure (inches of water)

Maximum

14"

Minimum

11"

Dimensions, Inches (H x W x D)

Heater

20 1/2 x 13 1/2 x 5

Carton

25 x 16 11/16 x 7 1/2

Weight (pounds)

Heater

14

Shipping

18

SPECIFICATIONS

Note:

Use only original replacement parts. This will protect your warranty cover-

age for parts replaced under warranty.

Parts Under Warranty

Contact authorized dealer from whom you purchased this product. If they cannot
supply original replacement part(s), call DESA International’s Customer Service
Department at 1-800-323-5190 for information.

When contacting your dealer or DESA International, have ready:

• your name
• your address
• model number of your heater
• how heater was malfunctioning
• type of gas used (propane/LP or natural gas)
• purchase date

Usually, we will ask you to return the defective part to the factory.

Parts Not Under Warranty

Contact authorized dealers of this product. If they cannot supply original replace-
ment part(s), call DESA International’s Parts Department at 1-800-972-7879 for
referral information.

When calling DESA International, have ready:

• model number of your heater
• the replacement part number

REPLACEMENT

PARTS

When gas pressure is too low

• pilot will not stay lit
• burner(s) will have delayed ignition
• heater will not produce specified heat
• propane/LP gas supply may be low

When gas quality is bad

• pilot will not stay lit
• burner(s) will produce flames and soot
• heater will backfire when lit

You may feel your gas pressure is too low or gas quality is bad. If so, contact your
local propane/LP gas supplier.