Trouble- shooting, Technical service, Warning – Desa CGP10R User Manual

Page 24

Advertising
background image

24

101866

TROUBLE-

SHOOTING

Continued

TECHNICAL

SERVICE

You may have further questions about installation, operation, or troubleshooting.
If so, contact DESA International’s Technical Service Department at 1-800-323-5190.

WARNING ICON

G 001

WARNING

If you smell gas

• Shut off gas supply.
• Do not try to light any appliance.
• Do not touch any electrical switch; do not

use any phone in your building.

• Immediately call your gas supplier from a

neighbor’s phone. Follow the gas supplier’s
instructions.

• If you cannot reach your gas supplier, call

the fire department.

IMPORTANT:

Operating heater where impurities in air exist may create odors. Cleaning

supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or
textiles, etc., create fumes. These fumes may mix with combustion air and create odors.

POSSIBLE
CAUSE

1. Heater burning vapors

from paint, hair spray,
glues, etc. (See

IMPOR-

TANT

statement above

2. Low fuel supply
3. Gas leak.

See Warn-

ing statement at
top of page

1. Not enough fresh air is

available

2. Low line pressure

3. ODS/pilot is partially

clogged

1. Gas leak.

See Warn-

ing statement at
top of page

2. Control valve defective

1. Foreign matter between

control valve and burner

2. Gas leak.

See Warn-

ing statement at
top of page

1. Not enough combus-

tion/ventilation air

REMEDY

1. Ventilate room. Stop

using odor-causing
products while heater is
running

2. Refill supply tank
3. Locate and correct all

leaks (see Checking Gas
Connections
, page 14)

1. Refer to Air for Combus-

tion and Ventilation
requirements (page 5)

2. Contact local propane/LP

gas company

3. Clean ODS/pilot (see

Cleaning and Mainte-
nance
, page 21)

1. Locate and correct all

leaks (see Checking Gas
Connections
, page 14)

2. Replace control valve

1. Take apart gas tubing and

remove foreign matter

2. Locate and correct all

leaks (see Checking Gas
Connections
, page 14)

1. Refer to Air for Combus-

tion and Ventilation
requirements (page 5)

OBSERVED
PROBLEM

Heater produces
unwanted odors

Heater shuts off in
use (ODS operates)

Gas odor even when
control knob is in
OFF position

Gas odor during
combustion

Moisture/condensation
noticed on windows

Advertising