Inspecting burner, Operating heater, Manual lighting procedure – Desa CGP10R User Manual

Page 19

Advertising
background image

19

101866

INSPECTING

BURNER

GRH/OV 007

GOOD PILOT/LP

Thermocouple

Check pilot flame pattern and burner flame pattern often.

PILOT FLAME PATTERN

Figure 19 shows a correct pilot flame pattern. Figure 20 shows an incorrect pilot
flame pattern. The incorrect pilot flame is not touching the thermocouple. This will
cause the thermocouple to cool. When the thermocouple cools, the heater will shut
down.

Pilot Burner

Figure 19 - Correct Pilot Flame Pattern

Thermocouple

GRH/OV 008

BAD PILOT/LP

Pilot Burner

Figure 20 - Incorrect Pilot Flame Pattern

If pilot flame pattern is incorrect, as shown in Figure 20

• turn heater off (see To Turn Off Gas to Appliance, above)
• see Troubleshooting, pages 21 through 24

OPERATING

HEATER

Continued

Continued

TO TURN OFF GAS TO APPLIANCE

Shutting Off Heater

1. Turn control knob clockwise

Clockwise

to the OFF position.

Shutting Off Burner Only (pilot stays lit)

1. Turn control knob clockwise

Clockwise

to the PILOT position.

MANUAL LIGHTING PROCEDURE

1. Remove front panel (see Figure 10, page 12).
2. Follow steps 1 through 5 under Lighting Instructions
, pages 16 and 17.
3. With control knob pressed in, strike match. Hold match to pilot until pilot

lights.

4. Keep control knob pressed in for 10 seconds after pilot is lit. After 10

seconds, release control knob.

5. Replace front panel.

Advertising