Operating heater – Desa CGP10R User Manual

Page 17

Advertising
background image

17

101866

4. Wait five (5) minutes to clear out any gas. Then smell for gas, including

near the floor. If you then smell gas, STOP! Follow “B” in the safety infor-
mation at the top of page 16. If you don’t smell gas, go to the next step.

5. Press in control knob, and turn counterclockwise

C-clockwise

to pilot position.

Keep control knob pressed for five seconds.

Note:

You may be running this heater for the first time after hooking up

to gas supply. If so, the control knob may need to be pressed in for 30
seconds. This will allow air to bleed from the gas system.

• If control knob does not pop up when released, contact a qualified

service person or gas supplier for repairs.

6. With control knob pressed in, push down and release ignitor button. This

will light pilot. The pilot is attached to the front of burner. If needed, keep
pressing ignitor button until pilot lights.

Note:

If pilot does not light, refer to Troubleshooting, pages 21 through 24.

Also contact a qualified service person or gas supplier for repairs. Until
repairs are made, light pilot with match. To light pilot with match, see
Manual Lighting Procedure
, page 19.

OPERATING

HEATER

Continued

Continued

Figure 17 - Pilot

Thermocouple

Ignitor Electrode

Pilot Burner

7. Keep control knob pressed in for 10 seconds after lighting pilot. After 10

seconds, release control knob.

Note:

If pilot goes out, repeat steps 3 through 7.

Advertising