Typical wiring diagrams, Page 4, I-320 – IOTA I-320 User Manual

Page 4: A.c. ballast

Advertising
background image

Page 4

UNSWITCHED

ORG (277V)
BLK (120V)

WHT/BLK

5 COMMON

WHITE

VIOLET

VIOLET

SWITCHED OR

UNSWITCHED LINE

LAMP

*LAMP

*AC / EMERGENCY

BLACK

WHITE

BLUE

BLUE

RED
RED

YELLOW
YELLOW

BLUE

BLUE/WHT

RED/WHT

RED

YELLOW

UNIT

CONNECTOR

TBTS / CHARGE

INDICATOR

COMMON

A.C.

Ballast

EMERGENCY

BALLAST

2LRSB_E

TWO LAMP RAPID START BALLAST

WHT/BLK

WHT/RED

RED OR RED/BLK (+)

SELECT PROPER VOLTAGE

LEAD. CAP UNUSED LEAD. REFER TO

AC INPUT WIRING ON ILLUSTRATION 3

OF INSTALLATION MANUAL FOR PROPER

INPUT CIRCUIT WIRING.
DO NOT MATE CONNECTOR UNTIL

INSTALLATION IS COMPLETE AND

AC POWER IS SUPPLIED.

LAMP SELECTOR LEADS—REFER

TO INSTALLATION INSTRUCTIONS,

LAMPS OPERATION SECTION FOR

VARIOUS OPTIONS
TEST ACCESSORY LEADS-

REFER TO INSTALLATION

INSTRUCTIONS FOR PROPER

POLARITY WIRING.

5

USE EITHER WHT/BLK LEAD

FOR WIRING THE COMMON.

REFER TO AC INPUT WIRING

ON ILLUSTRATION 3 OF

INSTALLATION MANUAL.

TYPICAL WIRING DIAGRAMS

For wiring diagrams of ballasts not shown, consult our Customer Service.

Rev. 071513
68322-061

1. ONE LAMP RAPID START BALLAST

2. TWO LAMP RAPID START BALLAST

3. TWO LAMP RAPID START BALLAST

4. THREE LAMP RAPID START BALLAST

5. ONE LAMP INSTANT START BALLAST

6. TWO LAMP INSTANT START BALLAST

7. THREE LAMP INSTANT START BALLAST

8. FOUR LAMP INSTANT START BALLAST

UNSWITCHED

ORG (277V)
BLK (120V)

WHT/BLK

5

COMMON

WHITE

VIOLET

VIOLET

SWITCHED OR

UNSWITCHED LINE

*LAMP

*AC / EMERGENCY

BLACK

WHITE

BLUE

BLUE

RED
RED

BLUE

BLUE/WHT

RED/WHT

RED

YELLOW

UNIT

CONNECTOR

TBTS / CHARGE

INDICATOR

COMMON

A.C.

Ballast

EMERGENCY

BALLAST

1LRSB_E

ONE LAMP RAPID START BALLAST

WHT/BLK

WHT/RED

RED OR RED/BLK (+)

SELECT PROPER VOLTAGE

LEAD. CAP UNUSED LEAD. REFER TO

AC INPUT WIRING ON ILLUSTRATION 3

OF INSTALLATION MANUAL FOR PROPER

INPUT CIRCUIT WIRING.
DO NOT MATE CONNECTOR UNTIL

INSTALLATION IS COMPLETE AND

AC POWER IS SUPPLIED.

LAMP SELECTOR LEADS—REFER

TO INSTALLATION INSTRUCTIONS,

LAMPS OPERATION SECTION FOR

VARIOUS OPTIONS
TEST ACCESSORY LEADS-

REFER TO INSTALLATION

INSTRUCTIONS FOR PROPER

POLARITY WIRING.

5

USE EITHER WHT/BLK LEAD

FOR WIRING THE COMMON.

REFER TO AC INPUT WIRING

ON ILLUSTRATION 3 OF

INSTALLATION MANUAL.

UNSWITCHED

ORG (277V)
BLK (120V)

WHT/BLK

5 COMMON

WHITE

VIOLET

VIOLET

TBTS / CHARGE

INDICATOR

SWITCHED OR

UNSWITCHED LINE

LAMP

LAMP

*LAMP

*AC / EMERGENCY

BLACK

WHITE

BLUE/WHT

BLUE/WHT

RED
RED

YELLOW

YELLOW

BLUE

BLUE/WHT

RED/WHT

RED

YELLOW

UNIT

CONNECTOR

COMMON

A.C.

Ballast

BLUE

BLUE

EMERGENCY

BALLAST

3LRSB_E

THREE LAMP RAPID START BALLAST

WHT/BLK

WHT/RED

RED OR RED/BLK (+)

SELECT PROPER VOLTAGE

LEAD. CAP UNUSED LEAD. REFER TO

AC INPUT WIRING ON ILLUSTRATION 3

OF INSTALLATION MANUAL FOR PROPER

INPUT CIRCUIT WIRING.
DO NOT MATE CONNECTOR UNTIL

INSTALLATION IS COMPLETE AND

AC POWER IS SUPPLIED.

LAMP SELECTOR LEADS—REFER

TO INSTALLATION INSTRUCTIONS,

LAMPS OPERATION SECTION FOR

VARIOUS OPTIONS
TEST ACCESSORY LEADS-

REFER TO INSTALLATION

INSTRUCTIONS FOR PROPER

POLARITY WIRING.

5

USE EITHER WHT/BLK LEAD

FOR WIRING THE COMMON.

REFER TO AC INPUT WIRING

ON ILLUSTRATION 3 OF

INSTALLATION MANUAL.

UNSWITCHED

ORG (277V)
BLK (120V)

WHT/BLK

5 COMMON

WHITE

VIOLET

VIOLET

SWITCHED OR

UNSWITCHED LINE

*LAMP

*AC / EMERGENCY

BLACK

WHITE

BLUE

BLUE

BLUE/WHT

RED/WHT

RED

YELLOW

UNIT

CONNECTOR

TBTS / CHARGE

INDICATOR

COMMON

A.C.

Ballast

RED

ONE LAMP INSTANT START BALLAST

1LISB_E

EMERGENCY

BALLAST

WHT/BLK

WHT/RED

RED OR RED/BLK (+)

6

SELECT PROPER VOLTAGE

LEAD. CAP UNUSED LEAD. REFER TO

AC INPUT WIRING ON ILLUSTRATION 3

OF INSTALLATION MANUAL FOR PROPER

INPUT CIRCUIT WIRING.
DO NOT MATE CONNECTOR UNTIL

INSTALLATION IS COMPLETE AND

AC POWER IS SUPPLIED.

LAMP SELECTOR LEADS—REFER

TO INSTALLATION INSTRUCTIONS,

LAMPS OPERATION SECTION FOR

VARIOUS OPTIONS
TEST ACCESSORY LEADS-

REFER TO INSTALLATION

INSTRUCTIONS FOR PROPER

POLARITY WIRING.

5

USE EITHER WHT/BLK LEAD

FOR WIRING THE COMMON.

REFER TO AC INPUT WIRING

ON ILLUSTRATION 3 OF

INSTALLATION MANUAL.
CONNECT BLU/WHT AND

RED/WHT WIRES TOGETHER

6

UNSWITCHED

ORG (277V)
BLK (120V)

WHT/BLK

5

COMMON

WHITE

RED OR RED/BLK (+)

SWITCHED OR

UNSWITCHED LINE

LAMP

*LAMP

*AC / EMERGENCY

BLACK

WHITE

BLUE

BLUE

RED

BLUE

BLUE/WHT

RED/WHT

RED

YELLOW

UNIT

CONNECTOR

TBTS / CHARGE

INDICATOR

COMMON

A.C.

Ballast

EMERGENCY

BALLAST

2LISB_2_E

TWO LAMP INSTANT START BALLAST

WHT/BLK

WHT/RED

VIOLET

VIOLET

6

SELECT PROPER VOLTAGE

LEAD. CAP UNUSED LEAD. REFER TO

AC INPUT WIRING ON ILLUSTRATION 3

OF INSTALLATION MANUAL FOR PROPER

INPUT CIRCUIT WIRING.
DO NOT MATE CONNECTOR UNTIL

INSTALLATION IS COMPLETE AND

AC POWER IS SUPPLIED.

LAMP SELECTOR LEADS—REFER

TO INSTALLATION INSTRUCTIONS,

LAMPS OPERATION SECTION FOR

VARIOUS OPTIONS
TEST ACCESSORY LEADS-

REFER TO INSTALLATION

INSTRUCTIONS FOR PROPER

POLARITY WIRING.

5 USE EITHER WHT/BLK LEAD

FOR WIRING THE COMMON.

REFER TO AC INPUT WIRING

ON ILLUSTRATION 3 OF

INSTALLATION MANUAL.
CONNECT BLU/WHT AND

RED/WHT WIRES TOGETHER

6

UNSWITCHED

ORG (277V)
BLK (120V)

WHT/BLK

COMMON

WHITE

VIOLET

VIOLET

SWITCHED OR

UNSWITCHED LINE

LAMP

LAMP

*LAMP

*AC / EMERGENCY

BLACK

WHITE

BLUE

BLUE

BLUE

RED

BLUE

BLUE/WHT

RED/WHT

RED

YELLOW

UNIT

CONNECTOR

TBTS / CHARGE

INDICATOR

COMMON

A.C.

Ballast

EMERGENCY

BALLAST

3LISB_E

THREE LAMP INSTANT START BALLAST

WHT/BLK

WHT/RED

RED OR RED/BLK (+)

SELECT PROPER VOLTAGE

LEAD. CAP UNUSED LEAD. REFER TO

AC INPUT WIRING ON ILLUSTRATION 3

OF INSTALLATION MANUAL FOR PROPER

INPUT CIRCUIT WIRING.
DO NOT MATE CONNECTOR UNTIL

INSTALLATION IS COMPLETE AND

AC POWER IS SUPPLIED.

LAMP SELECTOR LEADS—REFER

TO INSTALLATION INSTRUCTIONS,

LAMPS OPERATION SECTION FOR

VARIOUS OPTIONS
TEST ACCESSORY LEADS-

REFER TO INSTALLATION

INSTRUCTIONS FOR PROPER

POLARITY WIRING.

5

USE EITHER WHT/BLK LEAD

FOR WIRING THE COMMON.

REFER TO AC INPUT WIRING

ON ILLUSTRATION 3 OF

INSTALLATION MANUAL.
CONNECT BLU/WHT AND

RED/WHT WIRES TOGETHER

6

6

WHT/BLK

UNSWITCHED

ORG (277V)
BLK (120V)

WHT/BLK

5

COMMON

WHITE

VIOLET

VIOLET

SWITCHED OR

UNSWITCHED LINE

LAMP

LAMP

LAMP

*LAMP

*AC / EMERGENCY

BLACK

WHITE

RED
RED

BLUE
BLUE

YELLOW
YELLOW

BLUE

BLUE/WHT

RED/WHT

RED

YELLOW

UNIT

CONNECTOR

TBTS / CHARGE

INDICATOR

COMMON

A.C.

Ballast

EMERGENCY

BALLAST

4LISB_E

FOUR LAMP INSTANT START BALLAST

WHT/RED

RED OR RED/BLK (+)

6

SELECT PROPER VOLTAGE

LEAD. CAP UNUSED LEAD. REFER TO

AC INPUT WIRING ON ILLUSTRATION 3

OF INSTALLATION MANUAL FOR PROPER

INPUT CIRCUIT WIRING.
DO NOT MATE CONNECTOR UNTIL

INSTALLATION IS COMPLETE AND

AC POWER IS SUPPLIED.

LAMP SELECTOR LEADS—REFER

TO INSTALLATION INSTRUCTIONS,

LAMPS OPERATION SECTION FOR

VARIOUS OPTIONS
TEST ACCESSORY LEADS-

REFER TO INSTALLATION

INSTRUCTIONS FOR PROPER

POLARITY WIRING.

5 USE EITHER WHT/BLK LEAD

FOR WIRING THE COMMON.

REFER TO AC INPUT WIRING

ON ILLUSTRATION 3 OF

INSTALLATION MANUAL.
CONNECT BLU/WHT AND

RED/WHT WIRES TOGETHER

6

I-320

I-320

I-320

I-320

I-320

I-320

I-320

UNSWITCHED

ORG (277V)
BLK (120V)

WHT/BLK

5 COMMON

WHITE

SWITCHED OR

UNSWITCHED LINE

LAMP

*LAMP

*AC / EMERGENCY

BLACK
WHITE

RED
RED

BLUE
BLUE

YELLOW

BLUE

BLUE/WHT

RED/WHT

RED

YELLOW

UNIT

CONNECTOR

TBTS / CHARGE

INDICATOR

COMMON

A.C.

Ballast

VIOLET

VIOLET

EMERGENCY

BALLAST

2LRSB_E_4

TWO LAMP RAPID START BALLAST

WHT/BLK

RED OR RED/BLK (+)

WHT/RED

YELLOW

SELECT PROPER VOLTAGE

LEAD. CAP UNUSED LEAD. REFER TO

AC INPUT WIRING ON ILLUSTRATION 3

OF INSTALLATION MANUAL FOR PROPER

INPUT CIRCUIT WIRING.
DO NOT MATE CONNECTOR UNTIL

INSTALLATION IS COMPLETE AND

AC POWER IS SUPPLIED.

LAMP SELECTOR LEADS—REFER

TO INSTALLATION INSTRUCTIONS,

LAMPS OPERATION SECTION FOR

VARIOUS OPTIONS
TEST ACCESSORY LEADS-

REFER TO INSTALLATION

INSTRUCTIONS FOR PROPER

POLARITY WIRING.

5

USE EITHER WHT/BLK LEAD

FOR WIRING THE COMMON.

REFER TO AC INPUT WIRING

ON ILLUSTRATION 3 OF

INSTALLATION MANUAL.

I-320

TBTS

TBTS

TBTS

TBTS

TBTS

TBTS

TBTS

TBTS

SELECT PROPER VOLTAGE

LEAD. CAP UNUSED LEAD. REFER TO

AC INPUT WIRING ON ILLUSTRATION 3

OF INSTALLATION MANUAL FOR PROPER

INPUT CIRCUIT WIRING.
DO NOT MATE CONNECTOR UNTIL

INSTALLATION IS COMPLETE AND

AC POWER IS SUPPLIED.

LAMP SELECTOR LEADS—REFER

TO INSTALLATION INSTRUCTIONS,

LAMPS OPERATION SECTION FOR

VARIOUS OPTIONS
TEST ACCESSORY LEADS-

REFER TO INSTALLATION

INSTRUCTIONS FOR PROPER

POLARITY WIRING.

5

USE EITHER WHT/BLK LEAD

FOR WIRING THE COMMON.

REFER TO AC INPUT WIRING

ON ILLUSTRATION 3 OF

INSTALLATION MANUAL.
CONNECT BLU/WHT AND

RED/WHT WIRES TOGETHER

6

Wiring and Troubleshooting Tips are available on-line at http://www.iotaengineering.com/wiringtips.pdf

Advertising