Additional wiring diagrams, I-320, Three lamp rapid start ballast – IOTA I-320 User Manual

Page 5: Page 5, Insert, A.c. ballast

Advertising
background image

Page 5

ADDITIONAL WIRING DIAGRAMS

For wiring diagrams of ballasts not shown, consult our Customer Service.

SELECT PROPER VOLTAGE

LEAD. CAP UNUSED LEAD. REFER TO

AC INPUT WIRING ON ILLUSTRATION 3

OF INSTALLATION MANUAL FOR PROPER

INPUT CIRCUIT WIRING.
DO NOT MATE CONNECTOR UNTIL

INSTALLATION IS COMPLETE AND

AC POWER IS SUPPLIED.

LAMP SELECTOR LEADS—REFER

TO INSTALLATION INSTRUCTIONS,

LAMPS OPERATION SECTION FOR

VARIOUS OPTIONS
TEST ACCESSORY LEADS-

REFER TO INSTALLATION

INSTRUCTIONS FOR PROPER

POLARITY WIRING.

5

USE EITHER WHT/BLK LEAD

FOR WIRING THE COMMON.

REFER TO AC INPUT WIRING

ON ILLUSTRATION 3 OF

INSTALLATION MANUAL.
CONNECT BLU/WHT AND

RED/WHT WIRES TOGETHER

6

Insert

Rev. 071513
68322-061

Wiring and Troubleshooting Tips are available on-line at http://www.iotaengineering.com/wiringtips.pdf

1. THREE LAMP RAPID START BALLAST

4. FOUR LAMP RAPID START BALLAST

3. FOUR LAMP RAPID START BALLAST

UNSWITCHED

ORG (277V)
BLK (120V)

WHT/BLK

5 COMMON

WHITE

TBTS / CHARGE

INDICATOR

SWITCHED OR

UNSWITCHED LINE

*AC / EMERGENCY

BLACK

WHITE

RED

RED

BLUE
BLUE

BLUE

BLUE/WHT

RED/WHT

RED

YELLOW

UNIT

CONNECTOR

COMMON

A.C.

Ballast

ORANGE

ORANGE

VIOLET

VIOLET

THREE LAMP RAPID START BALLAST

3_LRSB_E_3

EMERGENCY

BALLAST

*LAMP

LAMP

LAMP

BLU/WHT

BLU/WHT

WHT/BLK

RED OR RED/BLK (+)

WHT/RED

YELLOW

YELLOW

BROWN

BROWN

SELECT PROPER VOLTAGE

LEAD. CAP UNUSED LEAD. REFER TO

AC INPUT WIRING ON ILLUSTRATION 3

OF INSTALLATION MANUAL FOR PROPER

INPUT CIRCUIT WIRING.
DO NOT MATE CONNECTOR UNTIL

INSTALLATION IS COMPLETE AND

AC POWER IS SUPPLIED.

LAMP SELECTOR LEADS—REFER

TO INSTALLATION INSTRUCTIONS,

LAMPS OPERATION SECTION FOR

VARIOUS OPTIONS
TEST ACCESSORY LEADS-

REFER TO INSTALLATION

INSTRUCTIONS FOR PROPER

POLARITY WIRING.

5 USE EITHER WHT/BLK LEAD

FOR WIRING THE COMMON.

REFER TO AC INPUT WIRING

ON ILLUSTRATION 3 OF

INSTALLATION MANUAL.

UNSWITCHED

ORG (277V)
BLK (120V)

WHT/BLK

5

COMMON

WHITE

TBTS / CHARGE

INDICATOR

SWITCHED OR

UNSWITCHED LINE

LAMP

*AC / EMERGENCY

BLACK

WHITE

RED

RED

ORG

ORG

BLUE

BLUE/WHT

RED/WHT

RED

YELLOW

UNIT

CONNECTOR

COMMON

A.C.

Ballast

BLUE

BLUE

VIOLET

VIOLET

FOUR LAMP RAPID START BALLAST

4LRSB_E_4

EMERGENCY

BALLAST

*LAMP

LAMP

LAMP

BLU/WHT
BLU/WHT

WHT/BLK

RED OR RED/BLK (+)

WHT/RED

YELLOW

YELLOW

BROWN

BROWN

SELECT PROPER VOLTAGE

LEAD. CAP UNUSED LEAD. REFER TO

AC INPUT WIRING ON ILLUSTRATION 3

OF INSTALLATION MANUAL FOR PROPER

INPUT CIRCUIT WIRING.
DO NOT MATE CONNECTOR UNTIL

INSTALLATION IS COMPLETE AND

AC POWER IS SUPPLIED.

LAMP SELECTOR LEADS—REFER

TO INSTALLATION INSTRUCTIONS,

LAMPS OPERATION SECTION FOR

VARIOUS OPTIONS
TEST ACCESSORY LEADS-

REFER TO INSTALLATION

INSTRUCTIONS FOR PROPER

POLARITY WIRING.

5

USE EITHER WHT/BLK LEAD

FOR WIRING THE COMMON.

REFER TO AC INPUT WIRING

ON ILLUSTRATION 3 OF

INSTALLATION MANUAL.

TBTS / CHARGE

INDICATOR

UNSWITCHED

SWITCHED OR

UNSWITCHED

LINE

COMMON

LAMP

*AC / EMERGENCY

BLACK

WHITE

BLUE/WHT

BLUE/WHT

RED
RED

YELLOW

YELLOW

BLUE

BLUE/WHT

RED/WHT

RED

YELLOW

UNIT

CONNECTOR

COMMON

A.C.

Ballast

BLUE

BLUE

VIOLET

VIOLET

FOUR LAMP RAPID START BALLAST

4LRSB_E_2

EMERGENCY

BALLAST

*LAMP

LAMP

LAMP

BROWN

BROWN

RED OR RED/BLK (+)

WHT/RED

SELECT PROPER VOLTAGE

LEAD. CAP UNUSED LEAD. REFER TO

AC INPUT WIRING ON ILLUSTRATION 3

OF INSTALLATION MANUAL FOR PROPER

INPUT CIRCUIT WIRING.
DO NOT MATE CONNECTOR UNTIL

INSTALLATION IS COMPLETE AND

AC POWER IS SUPPLIED.

LAMP SELECTOR LEADS—REFER

TO INSTALLATION INSTRUCTIONS,

LAMPS OPERATION SECTION FOR

VARIOUS OPTIONS
TEST ACCESSORY LEADS-

REFER TO INSTALLATION

INSTRUCTIONS FOR PROPER

POLARITY WIRING.

5 USE EITHER WHT/BLK LEAD

FOR WIRING THE COMMON.

REFER TO AC INPUT WIRING

ON ILLUSTRATION 3 OF

INSTALLATION MANUAL.

WHITE

WHT/BLK

5

ORG (277V)
BLK (120V)
WHT/BLK

I-320

I-320

I-320

TBTS

TBTS

TBTS

2. THREE LAMP RAPID START BALLAST

UNSWITCHED

ORG (277V)
BLK (120V)

WHT/BLK

5 COMMON

WHITE

TBTS / CHARGE

INDICATOR

SWITCHED OR

UNSWITCHED LINE

*AC / EMERGENCY

BLACK

WHITE

BLUE

BLUE/WHT

RED/WHT

RED

YELLOW

UNIT

CONNECTOR

COMMON

A.C.

Ballast

ORANGE

ORANGE

VIOLET

VIOLET

THREE LAMP RAPID START BALLAST

3_LRSB_E_HE

EMERGENCY

BALLAST

LAMP

LAMP

WHT/BLK

RED OR RED/BLK (+)

WHT/RED

YELLOW

YELLOW

BROWN

BROWN

SELECT PROPER VOLTAGE

LEAD. CAP UNUSED LEAD. REFER TO

AC INPUT WIRING ON ILLUSTRATION 3

OF INSTALLATION MANUAL FOR PROPER

INPUT CIRCUIT WIRING.
DO NOT MATE CONNECTOR UNTIL

INSTALLATION IS COMPLETE AND

AC POWER IS SUPPLIED.

LAMP SELECTOR LEADS—REFER

TO INSTALLATION INSTRUCTIONS,

LAMPS OPERATION SECTION FOR

VARIOUS OPTIONS
TEST ACCESSORY LEADS-

REFER TO INSTALLATION

INSTRUCTIONS FOR PROPER

POLARITY WIRING.

5 USE EITHER WHT/BLK LEAD

FOR WIRING THE COMMON.

REFER TO AC INPUT WIRING

ON ILLUSTRATION 3 OF

INSTALLATION MANUAL.

RED
RED

BLU/WHT
BLU/WHT

BLUE
BLUE

*LAMP

I-320

TBTS

Advertising