Typical wiring diagrams, Page 4, I-13-em-j – IOTA I-13-EM-J User Manual

Page 4

Advertising
background image

Page 4

UNIT

CONNECTOR

CHARGE

INDICATOR

TEST

SWITCH

WHITE

RED OR

RED/BLK (+)

WHT/BLK

FLEX

BLK (120V)

ORG (277V)

WHITE

WHT/BLK

BLUE/WHT

BLUE

YELLOW

YEL/BLK

BLUE

BLACK

UNSWITCHED LINE

COMMON

SWITCHED OR

UNSWITCHED

LINE

A.C.

BALLAST

*LAMP

WHT/BLK

WHT/RED

WHT/BLK

EMERGENCY

BALLAST

ONE LAMP MAGNETIC BALLAST

1LMBJ

DO NOT MATE CONNECTOR UNTIL

INSTALLATION IS COMPLETE AND

AC POWER IS SUPPLIED.
LAMP SELECTOR LEADS—REFER

TO INSTALLATION INSTRUCTIONS,

LAMP OPERATION SECTION FOR

VARIOUS OPTIONS.
TEST ACCESSORY LEADS-REFER

TO INSTALLATION INSTRUCTIONS

FOR PROPER POLARITY WIRING.

TYPICAL WIRING DIAGRAMS

For use with 2 pin, 5 through 13 watt lamps with integral starter only

Rev. 071513
68313-005

1. ONE LAMP MAGNETIC BALLAST

3. ONE LAMP ELECTRONIC BALLAST

5. TWO LAMP PARALLEL MAGNETIC BALLAST

7. TWO LAMP SERIES MAGNETIC BALLAST

2. ONE LAMP HIGH POWER FACTOR MAGNETIC BALLAST

4. TWO LAMP ELECTRONIC BALLAST

6. TWO LAMP PARALLEL HIGH POWER FACTOR MAGNETIC BALLAST

8. TWO LAMP SERIES HIGH POWER FACTOR MAGNETIC BALLAST

UNIT

CONNECTOR

CHARGE

INDICATOR

TEST

SWITCH

WHITE

RED OR

RED/BLK (+)

WHT/BLK

WHT/BLK

WHT/RED

WHT/BLK

FLEX

BLK (120V)

ORG (277V)

WHITE

WHITE

WHT/BLK

BLUE/WHT

BLUE

YELLOW

YEL/BLK

BLUE

BLACK

UNSWITCHED LINE

COMMON

SWITCHED OR

UNSWITCHED

LINE

A.C.

BALLAST

*LAMP

EMERGENCY

BALLAST

ONE LAMP HIGH POWER FACTOR MAGNETIC BALLAST

1LHPFMBJ

DO NOT MATE CONNECTOR UNTIL

INSTALLATION IS COMPLETE AND

AC POWER IS SUPPLIED.
LAMP SELECTOR LEADS—REFER

TO INSTALLATION INSTRUCTIONS,

LAMP OPERATION SECTION FOR

VARIOUS OPTIONS.
TEST ACCESSORY LEADS-REFER

TO INSTALLATION INSTRUCTIONS

FOR PROPER POLARITY WIRING.

UNIT

CONNECTOR

CHARGE

INDICATOR

TEST

SWITCH

WHITE

RED OR

RED/BLK (+)

WHT/BLK

WHT/BLK

WHT/RED

WHT/BLK

FLEX

BLK (120V)

ORG (277V)

WHITE

WHITE

WHT/BLK

BLUE/WHT

BLUE

YELLOW

YEL/BLK

BLUE

RED

BLACK

UNSWITCHED LINE

COMMON

SWITCHED OR

UNSWITCHED

LINE

A.C.

BALLAST

*LAMP

EMERGENCY

BALLAST

ONE LAMP ELECTRONIC BALLAST

1LEBJ

DO NOT MATE CONNECTOR UNTIL

INSTALLATION IS COMPLETE AND

AC POWER IS SUPPLIED.
LAMP SELECTOR LEADS—REFER

TO INSTALLATION INSTRUCTIONS,

LAMP OPERATION SECTION FOR

VARIOUS OPTIONS.
TEST ACCESSORY LEADS-REFER

TO INSTALLATION INSTRUCTIONS

FOR PROPER POLARITY WIRING.

UNIT

CONNECTOR

CHARGE

INDICATOR

TEST

SWITCH

WHITE

RED OR

RED/BLK (+)

WHT/BLK

WHT/BLK

WHT/RED

WHT/BLK

FLEX

BLK (120V)

ORG (277V)

WHITE

WHITE

WHT

WHT/BLK

BLUE/WHT

BLUE

YELLOW

YEL/BLK

BLACK

BLACK

UNSWITCHED LINE

COMMON

SWITCHED OR

UNSWITCHED

LINE

A.C.

BALLAST

*LAMP

LAMP

*AC/EMERGENCY LAMP

WHITE

BLACK

TWO LAMP ELECTRONIC BALLAST

EMERGENCY

BALLAST

2LEBJ

DO NOT MATE CONNECTOR UNTIL

INSTALLATION IS COMPLETE AND

AC POWER IS SUPPLIED.
LAMP SELECTOR LEADS—REFER

TO INSTALLATION INSTRUCTIONS,

LAMP OPERATION SECTION FOR

VARIOUS OPTIONS.
TEST ACCESSORY LEADS-REFER

TO INSTALLATION INSTRUCTIONS

FOR PROPER POLARITY WIRING.

UNIT

CONNECTOR

CHARGE

INDICATOR

TEST

SWITCH

WHITE

RED OR

RED/BLK (+)

WHT/BLK

WHT/BLK

WHT/RED

WHT/BLK

FLEX

BLK (120V)

ORG (277V)

WHITE

RED

WHT/BLK

BLUE/WHT

BLUE

YELLOW

YEL/BLK

BLUE

BLACK

UNSWITCHED LINE

COMMON

SWITCHED OR

UNSWITCHED

LINE

A.C.

BALLAST

*LAMP

LAMP

*AC/EMERGENCY LAMP

EMERGENCY

BALLAST

TWO LAMP PARALLEL MAGNETIC BALLAST

2LPMBJ

DO NOT MATE CONNECTOR UNTIL

INSTALLATION IS COMPLETE AND

AC POWER IS SUPPLIED.
LAMP SELECTOR LEADS—REFER

TO INSTALLATION INSTRUCTIONS,

LAMP OPERATION SECTION FOR

VARIOUS OPTIONS.
TEST ACCESSORY LEADS-REFER

TO INSTALLATION INSTRUCTIONS

FOR PROPER POLARITY WIRING.

UNIT

CONNECTOR

CHARGE

INDICATOR

TEST

SWITCH

WHITE

RED OR

RED/BLK (+)

WHT/BLK

WHT/BLK

WHT/RED

WHT/BLK

FLEX

BLK (120V)

ORG (277V)

WHITE

WHITE

BLUE

WHT/BLK

BLUE/WHT

BLUE

YELLOW

YEL/BLK

BLUE

BLACK

UNSWITCHED LINE

COMMON

SWITCHED OR

UNSWITCHED

LINE

A.C.

BALLAST

*LAMP

LAMP

*AC/EMERGENCY LAMP

TWO LAMP PARALLEL HIGH POWER FACTOR MAGNETIC BALLAST

EMERGENCY

BALLAST

2LPHPFMBJ

DO NOT MATE CONNECTOR UNTIL

INSTALLATION IS COMPLETE AND

AC POWER IS SUPPLIED.
LAMP SELECTOR LEADS—REFER

TO INSTALLATION INSTRUCTIONS,

LAMP OPERATION SECTION FOR

VARIOUS OPTIONS.
TEST ACCESSORY LEADS-REFER

TO INSTALLATION INSTRUCTIONS

FOR PROPER POLARITY WIRING.

UNIT

CONNECTOR

CHARGE

INDICATOR

TEST

SWITCH

WHITE

RED OR

RED/BLK (+)

WHT/BLK

WHT/BLK

WHT/RED

WHT/BLK

FLEX

BLK (120V)

ORG (277V)

WHITE

WHT

WHT/BLK

BLUE/WHT

BLUE

YELLOW

YEL/BLK

BLUE

BLACK

UNSWITCHED LINE

COMMON

SWITCHED OR

UNSWITCHED

LINE

A.C.

BALLAST

*LAMP

LAMP

*AC/EMERGENCY LAMP

EMERGENCY

BALLAST

TWO LAMP SERIES MAGNETIC BALLAST

2LSMBJ

DO NOT MATE CONNECTOR UNTIL

INSTALLATION IS COMPLETE AND

AC POWER IS SUPPLIED.
LAMP SELECTOR LEADS—REFER

TO INSTALLATION INSTRUCTIONS,

LAMP OPERATION SECTION FOR

VARIOUS OPTIONS.
TEST ACCESSORY LEADS-REFER

TO INSTALLATION INSTRUCTIONS

FOR PROPER POLARITY WIRING.

UNIT

CONNECTOR

CHARGE

INDICATOR

TEST

SWITCH

WHITE

RED OR

RED/BLK (+)

WHT/BLK

WHT/BLK

WHT/RED

WHT/BLK

FLEX

BLK (120V)

ORG (277V)

WHITE

WHITE

RED

WHT/BLK

BLUE/WHT

BLUE

YELLOW

YEL/BLK

BLUE

BLACK

UNSWITCHED LINE

COMMON

SWITCHED OR

UNSWITCHED

LINE

A.C.

BALLAST

*LAMP

LAMP

*AC/EMERGENCY LAMP

TWO LAMP SERIES HIGH POWER FACTOR MAGNETIC BALLAST

EMERGENCY

BALLAST

2LSHPFMBJ

DO NOT MATE CONNECTOR UNTIL

INSTALLATION IS COMPLETE AND

AC POWER IS SUPPLIED.
LAMP SELECTOR LEADS—REFER

TO INSTALLATION INSTRUCTIONS,

LAMP OPERATION SECTION FOR

VARIOUS OPTIONS.
TEST ACCESSORY LEADS-REFER

TO INSTALLATION INSTRUCTIONS

FOR PROPER POLARITY WIRING.

I-13-EM-J

I-13-EM-J

I-13-EM-J

I-13-EM-J

I-13-EM-J

I-13-EM-J

I-13-EM-J

I-13-EM-J

Wiring and Troubleshooting Tips are available on-line at http://www.iotaengineering.com/wiringtips.pdf

Advertising