O table 7-2 a, Table 7-2 l, 40 front panel interface – Lab.gruppen PLM 20000Q User Manual

Page 46

Advertising
background image

40

Front Panel Interface

PLM Series Operation Manual rev 1.2.3

PLM
Model

Warning

Type

LED

No.

On Screen
Warning Text

Event Log Text

20000Q Amp Temp Limit

Frame

1

ATL ACTIVE

N/A

ALL

AES Clock Slipping

Module

1

CLOCK SLIPPING

AES Clock Slipping

ALL

Amp Temp Warning

Channel

5-8

TEMP WARN:CH

Temp warning: Amp Channel

20000Q BEL Active

Frame

1

BEL ACTIVE

N/A

ALL

Controller Offline

Frame

1

CTRL OFFLINE

N/A

ALL

Frame Offline

-

1

OFFLINE

Frame Offline

ALL

Load Not Verified

Module
Channel

2+3

5-8

LOAD NOT VER

LoadSmart: Load Not Verified

ALL

Load Uncertain

Channel

5-8

UNCERTAIN LOAD Uncertain About Load Type

20000Q PSU Mains Glitch

Frame

1

MAINS GLITCH

Glitch on Mains Voltage Detected

20000Q PSU Power Limit

Frame

1

PAL ACTIVE

N/A

20000Q PSU Temp Limit

Frame

1

PTL ACTIVE

N/A

ALL

PSU Temp Warning

Frame

1

TEMP WARN: PSU Temp Warning: Power Supply Unit

ALL

Sense Fault

Frame

1

SENSE FAULT

Frame warning: Sense Fault

ALL

Speaker Mag Temp Warning

Channel

5-8

TEMP WARN:MAG Temp Warning: Speaker Magnet

ALL

Speaker Over Count

Channel

5-8

OVER SPKR CNT

Over Speaker Count

ALL

Speaker Under Count

Channel

5-8

UNDER SPKR CNT Under Speaker Count

ALL

Speaker VC Temp Warning

Channel

5-8

TEMP WARN:VC

Temp Warning: Speaker Voice-Coil

ALL

SpeakerSafe Not Started

Ch

5-8

SPKSAFE INACT

SpeakerSafe Not Started

ALL

SpeakerSafe Precision Low

Ch

5-8

LM PREC. LOW

SpeakerSafe Precision Low

20000Q Under Voltage Limit

Frame

1

UVL ACTIVE

N/A

Table 7-2: Warning Conditions (Yellow LED)