76 appendix – Lab.gruppen PLM 20000Q User Manual

Page 82

Advertising
background image

76

Appendix

PLM Series Operation Manual rev 1.2.3

Model

Displayed Text

Event Log Text

Category Description

ALL

TEMP FLT:PSU

Temp Fault: Power Supply Unit

Fault

The temperature of the PLM’s PSU has
exceeded its safety limit.

ALL

TEMP FLT:VC

Temp Fault: Speaker Voice Coil

Fault

The temperature of the speaker voice
coil (estimated by SpeakerSafe) has
exceeded the manufacturers’ recom-
mended maximum.

ALL

TEMP WARN:
PSU

Temp warning: Power Supply
Unit

Warning

High temperature in the Power Supply
Unit.

ALL

TEMP WARN:CH

Temp Warning: Amp Channel

Warning

High temperature in the power output
stage.

ALL

TEMP
WARN:MAG

Temp Warning: Speaker
Magnet

Warning

The temperature of the speaker magnet
is high (estimated by SpeakerSafe).

ALL

TEMP WARN:VC

Temp Warning: Speaker
Voice-Coil

Warning

The temperature of the speaker voice
coil is high (estimated by SpeakerSafe).

ALL

UNCERTAIN
LOAD

Uncertain About Load Type

Warning

When speaker Fingerprints are taken a
tolerance band is also defined to take
into account production variations. If
LoadSmart results lie in this band a
Load uncertainty warning results. The
user should re-check the load and if
all appears to be correct it is likely that
normal operation will result.

ALL

UNDER SPKR
CNT

Under Speaker Count

Warning

A higher load impedance has been
measured than was predicted by the
Load Library for the assigned speaker
type.

20000Q UVL ACTIVE

N/A

Warning

The Under Voltage limiter is active as the
mains supply has fallen between 65 and
80 Volts. Output power is descreased to
ensure mains distribution does not sag.

ALL

VHF FAULT

Channel Fault: Very High
Frequency

Fault

An exceptionally high level of continuous
HF has been detected at the PLM’s
power output stage.

ALL

VOLTAGE CLIP

n/a

Fault

The peak voltage at the output terminals
has exceeded the user-defined safe
maximum.

ALL

WRONG LOAD

Load Type / Routing Mismatch

Fault

LoadSmart is measuring load charac-
teristics which differ from those of the
assigned speaker type.

Table 9-1: Warning, Fault and Mute Indications (alphabetical by LCD Text / Event Log Text)

Advertising