60 front panel interface – Lab.gruppen PLM 20000Q User Manual

Page 66

Advertising
background image

60

Front Panel Interface

PLM Series Operation Manual rev 1.2.3

To recall an existing Frame Preset, use the rotary encoder to select the required Preset then press the
RECALL button to overwrite the current configuration.

Frame Presets must initially be created in the Lake

Controller, and stored as a Preset using the Lake

Controller or Lake Preset Manager.

Up to 100 Frame Presets can be stored in the device. The data within a Frame Preset includes the configura-
tion of all Modules in the Frame including levels, crossovers, EQ, input mixer, and output routing.

As Frame Presets are stored within the device, complete processor configurations can be recalled without
connecting the device to a PC.

7.11.8 Load Monitor Menu (LoadSmart)

MENU > LOAD MON

Figure 7-20: Load Monitor Menu

7.11.8.1 Configure # of Cabinets in Parallel

This option allows selection of the number of speaker cabinets connected to each PLM output channel.
Select individual or multiple outputs and use the rotary encoder to set the value from 1 to 4. This value is
used by LoadSmart and SpeakerSafe to confirm the correct connection and status of the speakers con-
nected to each PLM channel.

7.11.8.2 LoadSmart Verification

Select this option to initiate LoadSmart verification, then select YES to continue. LoadSmart performs a
rapid test of all output channels, and displays the results on the LCD a few seconds later.

Advertising
This manual is related to the following products: