74 appendix – Lab.gruppen PLM 20000Q User Manual

Page 80

Advertising
background image

74

Appendix

PLM Series Operation Manual rev 1.2.3

Model

Displayed Text

Event Log Text

Category Description

ALL

INPUT MUTE

Input Mute

Mute

The audio signal has been muted at the
input router of the Lake Processor.

ALL

LM PREC. LOW

Speakersafe precision low

Warning

A SpeakerSafe warning indicating insuf-
ficient data to produce reliable results.
This may occur, for example, if a channel
is being driven at a very low level.

ALL

LOAD NOT VER

LoadSmart: Load Not Verified

Warning

A Module containing a Fingerprint has
been loaded, but the load is yet to be
verified with LoadSmart.

20000Q MAINS <65 V

Frame fault: PSU mains <65 V

Fault

Mains input voltage is below 65 Volts
RMS.

20000Q MAINS >270 V

Frame fault: PSU mains >270 V Fault

Mains input voltage is above 270 Volts
RMS.

20000Q MAINS >400 VPK Frame fault: PSU mains >400

VPK

Fault

Mains input voltage is above 400 Volts
Peak.

20000Q MAINS GLITCH

Glitch on mains voltage
detected

Warning

A glitch (missing cycles) on mains input
was detected.

ALL

MOD. IN MUTE

Module Input Mute

Mute

The audio signal has been muted at the
Module input of the Lake processor.

ALL

MOD. OUT MUTE Module Output Mute

Mute

The audio signal has been muted in the
output stage of the Lake processor.

ALL

MODULE CLIP

n/a

Clip

The signal level on the outputs of the
Lake processing module is too high and
is clipping.

ALL

n/a

LoadSmart Verification

Event

LoadSmart load verification is in
progress.

ALL

n/a

Sound Source Changed

Event

The input router has changed sound
source.

20000Q NEED SERVICE:1

Frame fault: Need Service: 1

Fault

Service required, contact your dealer.

20000Q NEED SERVICE:2

Frame fault: Need Service: 2

Fault

Service required, contact your dealer.

20000Q NEED SERVICE:3

Frame fault: Need Service: 3

Fault

Service required, contact your dealer.

20000Q NEED SERVICE:4

Frame fault: Need Service: 4

Fault

Service required, contact your dealer.

20000Q NEED SERVICE:5

Frame fault: Need Service: 5

Fault

Service required, contact your dealer.

20000Q NEED SERVICE:6

Frame fault: Need Service: 6

Fault

Service required, contact your dealer.

20000Q NEED SERVICE:7

Frame fault: Need Service: 7

Fault

Service required, contact your dealer.

20000Q NEED SERVICE:8

Frame fault: Need Service: 8

Fault

Service required, contact your dealer.

ALL

NO INPUT

No Input Source

Fault

The chosen input type has been
deselected or lost and the input type
selector has no alternative input sources
in the priority list.

ALL

NO LOAD

Channel Fault: No Load
Detected

Fault

No load detected at the power output
channel.

ALL

OFFLINE

Frame Offline

Warning

The Lake Controller cannot communicate
with this Lake device.

Advertising