Manikin Preparation Before Use

Inserting Fluids into the Umbilical Reservoir
Use a syringe to insert fluid into the abdominal reservoir. Do
not fill more than 40 ml.

Attaching the Umbilical Cord
Lubricate the end of the umbilical cord to be inserted with liq-
uid soap. Squeeze and press the umbilical cord into the umbili-
cal opening. The cord should be pressed at least 50mm (2 inch-
es) into the opening, but need not be pushed further down.

To remove, gently pull on the umbilical cord.

Changing Eye Pupils

1. Open the eyelids wide, taking care not to rip the faceskin.
2. Using the suction cup provided in the Eye Kit (see page 3,

Optional Accessories) or the edge of your fingernail, gently
remove the pupil from the eye.

3. Replace with the pupil of choice, using the small suction cup

provided in the Eye Kit or gently press pupil into place with
finger.

Inserting the Meconium Module

1. Insert the module with a finger - do not use force.

Note: Do not add lubricant to the module.
Note: Do not insert the meconium module past uvula.

2. A suction catheter @ 100 mmHg will remove the

meconium module.

3. A tether line has been added to ensure removal of the ob-

ject.

For intubation following the removal of the meconium module,
add Aiway Lubricant to the ET-tube before intubation.