Operation and maintenance guidelines – Desa (V)G36 User Manual

Page 13

Advertising
background image

www.desatech.com

116010-01C

13

IMPORTANT:

The glass must be allowed to

warm slowly and evenly. The tempered glass will

withstand a gradual temperature rise to 550° F,

which is more than a normal fire will generate.

Such materials as pitch/wax laden logs, very dry

mill end lumber and large amounts of paper or

cardboard boxes can create an excessively hot fire

and should not be burned in this fireplace. Always

keep the fire well back from the doors and never

allow flames to contact the glass.

WARNING: Fireplaces

equipped with glass doors

should be operated only with

doors fully opened or doors fully

closed. Doors, if left partly open,

may draw gas and flame out of

the fireplace opening creating

risks of both fire and smoke.

Cleaning Glass

Clean glass with any commercial glass cleaner or

soap and water. Do not use any abrasive material

to clean glass. Do not clean glass with any cool

water if glass is still hot from the fire and smoke.

A gas line or gas log lighter may be installed for the

purpose of installing a vented or vent-free deco-

rative gas appliance incorporating an automatic

shutoff device and complying with the Standard

for Decorative Gas Appliances for Installation in

Vented Fireplaces, ANSI Z21.60 or American Gas

Association draft requirements for Gas Fired Log

Lighters for Wood Burning Fireplaces, Draft NO.

4 dated August, 1993.

If you wish to install an unvented (vent-free) gas

log set, only unvented gas log sets which have been

found to comply with the standard for unvented

room heaters, ANSI Z21.11.2 are to be installed

in this fireplace.

OUTSIDE AIR AND DAMPER
HANDLE OPERATION

The damper handle, which opens and closes the

damper blade, is located in the upper front face

of the fireplace. Pushing the handle forward and

up through the keyway slot will free damper

blade to automatically open. Pushing the handle

forward and down will lock damper blade closed

(see Figure 25).

operaTion and

MainTenance guidelineS

Continued

Figure 25 - Operating Damper Handle

Damper
Weight

To Close
Damper

To Open
Damper

Damper
Weight

The outside air kit lever is located at the left and

right hand sides of fireplace (see Figure 26). Lift-

ing lever up will free the outside air door to open.

Pulling lever down will lock the door.

WARNING: Risk of fire! Re-

place grate with DESA model

109496-03 grate only. This grate

has been designed to keep the

operation of your fireplace safe

and efficient.

Open Position

Closed Position

Figure 26 - Outside Air Kit Lever

Advertising