Venting installation – Desa (V)G36 User Manual

Page 6

Advertising
background image

www.desatech.com

116010-01C

6

Figure 6 - Lineal Gain

LINEAL GAIN

PART NO.

DESCRIPTION

GAIN

Georgian

Fireplace

66

1

/



"

12-12DM

12-12HT

Pipe Section

10

5

/

8

"

18-12DM

18-12HT

Pipe Section

16

5

/

8

"

24-12DM

24-12HT

Pipe Section

3

5

/

8

"

36-12DM

36-12HT

Pipe Section

34

5

/

8

"

48-12DM

48-12HT

Pipe Section

46

5

/

8

"

RLT-12D

RLT-12HT

Round Termination

7

3

/

4

"*

STL-12D

Square Chase-Top

with Slip Section

7" to 15"*

* The lineal gain for the terminations is mea-
sured to the flue gas outlet height.

Hemmed
End

1

3

/

8

"

Stainless
Inner Pipe

15" Galvanized
Outer Pipe

ASSEMBLY AND INSTALLATION OF
DOUBLE WALL CHIMNEY SYSTEM

Each double wall chimney section consists of a

galvanized outer pipe, a stainless steel inner flue

pipe and a wire spacer. The pipe sections must be as-

sembled independently as the chimney is installed.

When connecting chimney directly to the fireplace,

the inner flue pipe section must be installed first

with the lanced side up. The outer pipe section can

then be installed over the flue pipe section with the

hemmed end up. Press down on each pipe section

until the lances securely engage the hem on the fire-

place starter. The wire will assure the proper spacing

between the inner and outer pipe sections.

Continue to assemble chimney sections as outlined

above, making sure that both the inner and outer

pipe sections are locked together. When install-

ing double wall snap-lock chimney together, it is

important to assure the joint between the chimney

sections is locked. Check by pulling chimney

upward after locking. The chimney will not come

apart if properly locked. It is not necessary to add

screws to keep the chimney together (exception,

see Figure 9, page 8).

VenTing inSTallaTion

OPTIONAL OUTSIDE AIR KIT
(MODEL AK4/AK4F)

The installation of an outside air kit should be per-

formed during the rough framing of the fireplace

due to the nature of it's location. Outside combus-

tion air is accessed through a vented crawl space

(AK4F) or through a sidewall (AK4).

CAUTION: Combustion air

inlet ducts shall not terminate

in attic space.

Figure 5 - Outside Air Kit

Secure to Collars with Metal Tape,
Screws or Straps (Min. 1/4" x 20" size)

Air Inlet
Location
Must Allow
For Bushes
or Snow

Vent Hood
Required for
Wall Installation

Air Inlet
Eyebrow

Vented Crawl Space
(Check Local Codes
Before Installing in a
Vented Crawl Space)

CHIMNEY PIPE

The DESA chimney system consists of 12", 18",

24", 36" and 48" snap-lock, double-wall pipe

segments, planned for maximum adaptability

to individual site requirements. Actual lengths

gained after fitting overlaps must be taken into

consideration (lineal gain) and are given in the

lineal gain chart (see Figure 6). Lineal Gain is the

actual measurable length of a part after two or more

parts are connected. For Canada, use chimney parts

designated "HT".

WARNING: The opening in the

collar around the chimney at the

top of the fireplace must not be

obstructed. Never use blown insula-

tion to fill the chimney enclosure.