Desa CGFP28PT User Manual

Unvented (vent-free) propane/lp gas fireplace, Owner’s operation and installation manual, Cgfp28p and cgfp28pt

Advertising
background image

Shown with optional
cabinet mantel and
hearth base.

®

WARNING: If the information in this manual is not
followed exactly, a fire or explosion may result caus-
ing property damage, personal injury, or loss of life.

— Do not store or use gasoline or other flammable

vapors and liquids in the vicinity of this or any
other appliance.

— WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.
• Do not touch any electrical switch; do not use

any phone in your building.

• Immediately call your gas supplier from a

neighbor’s phone. Follow the gas supplier’s
instructions.

• If you cannot reach your gas supplier, call the

fire department.

— Installation and service must be performed by a

qualified installer, service agency, or the gas
supplier.

WARNING: Improper installa-
tion, adjustment, alteration, ser-
vice, or maintenance can cause
injury or property damage. Re-
fer to this manual for correct
installation and operational pro-
cedures. For assistance or ad-
ditional information consult a
qualified installer, service
agency, or the gas supplier.

WARNING: This is an unvented
gas-fired heater. It uses air (oxy-
gen) from the room in which it is
installed. Provisions for ad-
equate combustion and venti-
lation air must be provided.
Refer to

Air for Combustion and

Ventilation

section on page 4 in

this manual.

Save this manual for future reference.

OWNER’S OPERATION AND INSTALLATION

MANUAL

UNVENTED (VENT-FREE)

PROPANE/LP GAS FIREPLACE

CGFP28P

AND

CGFP28PT

This appliance may be installed in an aftermarket* manufactured (mobile) home, where not prohibited
by state or local codes.

* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer