103414

UNVENTED PROPANE/LP GAS FIREPLACE

CGFP28P and CGFP28PT

42"

16"

Figure 23 - Placing Hearth Base Acces-
sory Against Wall

Figure 22 - Location of Nailing Flanges

Nailing
Flanges

INSTALLATION

Continued

INSTALLATION
CLEARANCES

Note: Clearances are the same if
using optional cabinet mantel or built-
in installation.

WARNING: Maintain the mini-

mum clearances. If you can, pro-
vide greater clearances from
floor, ceiling, and adjoining wall.

Carefully follow the instructions below. This
will ensure safe installation.

Minimum Wall and Ceiling
Clearances (see Figure 21)

A. Clearances from the side of the fire-

place opening to any combustible wall
should not be less than 16 inches for a
cabinet mantel or 12 inches for a cor-
ner installation.

B. Clearances from the top of the fireplace

opening to the ceiling should not be less
than 42 inches.

Note:

The instructions below show installa-

tion using the GMC11F/GMC12U/
GMC13F series cabinet mantel and the
GC3333F/GC3334U/GC3335F series
hearth base accessories (see Accessories,
page 32). A brass trim kit is included with
each mantel accessory. The hearth base ac-
cessory shown is optional for this installa-
tion. You can install fireplace and cabinet
mantel directly on the floor.

1.

Assemble cabinet mantel, brass trim
kit, and hearth base. Assembly instruc-
tions are included with each accessory.

2.

If installing an optional blower acces-
sory (see Accessories, page 32). Install
a properly grounded 120 volt, three
prong electrical outlet at fireplace lo-
cation if outlet is not there. If possible,
locate outlet so cabinet mantel will
cover it when installed (see Figure 24).

3.

Break off nailing flanges (see Figure
22) with hammer or pliers.

4.

Place mantel and base in desired loca-
tion. Place heater in front opening of
mantel. Make sure all pieces fit prop-
erly. Remove mantel.

5.

Mark floor and base or wall for gas line
entrance. Make sure there is enough
clearance between heater and mantel
for gas line.

IMPORTANT:

Make sure

there are no electrical lines where gas
piping will go through floor or wall.

WARNING: For conventional

installation, it is recommended
you use the cabinet mantel or
hearth base specified in this
manual. Surface clearances may
not be sufficient with other cabi-
net mantels and hearth bases.
This may create a fire hazard. See
Accessories, page 32, for correct
mantels and hearth bases.

CONVENTIONAL FIREPLACE
INSTALLATION

Figure 21 - Minimum Clearance to Wall
and Ceiling

MINIMUM
CLEARANCE
Side Wall - 16 "
Ceiling - 42"
Floor - 0"

Electrical Outlet

Hearth Base

Flexible Gas
Line

Gas Line
Access
Hole

6.

Place hearth base accessory against
wall at installation location. Cut an ac-
cess hole in hearth base top to run flex-
ible gas line to fireplace (see Figure 24).
Make sure to locate access hole so cabi-
net mantel will cover it when installed.

Note:

You can secure base to floor us-

ing wood screws. Countersink screw
heads and putty over.

7.

Install gas piping to fireplace location.
This installation includes an approved
flexible gas line (if allowed by local
codes) after the manual shutoff valve.
The flexible gas line must be the last
item installed on the gas piping. See In-
stalling Gas Piping to Fireplace Loca-
tion
, page 14.

8.

Carefully place fireplace on top of
hearth base (Figure 24, page 13). Be
careful not to scratch or damage hearth
base.

Note:

You can secure fireplace to

hearth or floor. Open louver door. Lo-
cate screw holes in bottom of base.
Secure with wood screws through these
holes and into hearth or floor.

Conventional installation of this fireplace
involves installing fireplace along with the
corner, face, or cabinet mantel and hearth
base accessories against a wall in your home.