INSPECTING
BURNERS

Check pilot flame pattern and burner flame
patterns often.

PILOT FLAME PATTERN

Figure 45 shows a correct pilot flame pattern.
Figure 46 shows an incorrect pilot flame
pattern. The incorrect pilot flame is not touch-
ing the thermocouple. This will cause the
thermocouple to cool. When the thermo-
couple cools, the fireplace will shutdown.

If pilot flame pattern is incorrect, as shown
in Figure 46

• turn fireplace off (see To Turn Off Gas to

Appliance, page 18 [Thermostat-con-
trolled models} or column 1, this page,
[Manually-controlled models])

• see Troubleshooting, pages 22 through 24

Thermocouple

Pilot Burner

Figure 45 - Correct Pilot Flame Pattern

Figure 46 - Incorrect Pilot Flame Pattern

FRONT BURNER FLAME
PATTERN

Figure 47 shows correct front burner flame
pattern. Figure 48 shows incorrect front
burner flame pattern. The incorrect burner
flame pattern shows yellow tipping at top of
blue flame.

WARNING: If front burner

flame pattern shows yellow tip-
ping, your fireplace could pro-
duce increased levels of carbon
monoxide. Follow instructions at
bottom of this page. Yellow flame
on rear burner is normal.

NOTICE: Do not mistake orange
flames with yellow tipping. Dirt
or other fine particles are burned
by fireplace, causing brief
patches of orange flame.

If front burner flame pattern is incorrect, as
shown in Figure 48

• turn fireplace off (see To Turn Off Gas to

Appliance, page 18 [Thermostat-con-
trolled models} or column 1, this page,
[Manually-controlled models])

• see Troubleshooting, pages 22 through 24

Figure 48 - Incorrect Front Burner Flame
Pattern

Figure 47 - Correct Front Burner Flame
Pattern

Thermocouple

Pilot Burner

WARNING: Do not operate

heater between pilot and high
positions.

CAUTION: Do not try to ad-

just heating levels by using the
manual shutoff valve.

The variable control valve can be set to
any heat setting and flame height de-
sired, by simply turning the control knob
until that setting is attained. Even the
lowest setting provides realistic flames
and glowing embers from two burners.
Selecting higher settings produces
greater heat output. This results in in-
creased heating comfort.

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Fireplace

1.

Turn control knob clockwise

Clockwise

to the HIGH position.

2.

Slightly depress control knob and
turn clockwise

Clockwise

to the PILOT

position.

3.

Slightly depress control knob and
turn clockwise

Clockwise

to the OFF

position.

Shutting Off Burners Only (pilot
stays lit)

1.

Turn control knob clockwise

Clockwise

to the HIGH position.

2.

Press in and turn clockwise

Clockwise

to the PILOT position.

OPERATING
FIREPLACE

Continued

Yellow Tipping At
Top of Blue Flame

VARIABLE MANUAL

CONTROL OPERATION

MANUAL LIGHTING

PROCEDURE

1.

Follow steps 1 through 5 under Light-
ing Instructions
, page 19.

2.

Depress control knob and light pilot
with match.

3.

Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob. Now
follow step 8, page 19.