Installation, Continued – Desa CGFP28PT User Manual

Page 16

Advertising
background image

16

103414

UNVENTED PROPANE/LP GAS FIREPLACE

CGFP28P and CGFP28PT

ON

POSITION

OFF

POSITION

INSTALLATION

Continued

Test Pressures Equal To or Less Than
1/2 PSIG

1.

Close manual shutoff valve (see Fig-
ure 34).

2.

Pressurize supply piping system by ei-
ther using compressed air or opening
propane supply tank valve.

3.

Check all joints from propane supply
tank to manual shutoff valve (see Fig-
ure 35). Apply mixture of liquid soap
and water to gas joints. Bubbles form-
ing show a leak.

4.

Correct all leaks at once.

Pressure Testing Fireplace Gas
Connections

1.

Open manual shutoff valve (see Fig-
ure 34).

2.

Open propane supply tank valve.

3.

Make sure control knob of fireplace is
in the OFF position.

4.

Check all joints from manual shutoff
valve to thermostat gas valve (see Fig-
ure 35). Apply mixture of liquid soap
and water to gas joints. Bubbles form-
ing show a leak.

5.

Correct all leaks at once.

6.

Light fireplace (see Operating Fire-
place,
pages 18 and 19 [Thermostat-
controlled models] or pages 19 and 20
[Manually-controlled models]). Check
all other internal joints for leaks.

7.

Turn off fireplace (see To Turn Off Gas
to Appliance
, page 18, [Thermostat-
controlled models] or page 20 [Manu-
ally-controlled models]).

Figure 34 - Manual Shutoff Valve

Open

Manual
Shutoff
Valve

Figure 35 - Checking Gas Joints

Propane
Supply
Tank

Manual Gas Valve

Manual Shutoff Valve

Closed

Advertising
This manual is related to the following products: