Tube replacement – Rocktron Vendetta 100W 2x12 Combo Amp User Manual

Page 12

Advertising
background image

- 12 -

Tube Replacement


POWER TUBE TEST POINTS USEAGE.

Please note that any adjustments, modifications, upgrades, etc
made to the VENDETTA may void the warranty. All work should be
performed by a qualified technician.

This feature on the rear panel provides a convenient point for measuring the idle current in the

power tubes without disassembling the unit. Different tube types can be installed and used in

the VENDETTA and biasing has been simplified. The instructions below explain how it works.



CAUTION!! DO NOT EXCEED THE VALUESSHOWN. This will shorten tube life, cause
possible tube failure and damage to the amplifier.

A digital voltmeter capable of displaying DC voltage from 0 to 200 millivolts is required. This can be an

inexpensive type found at most electronic suppliers such as Radio Shack. It is not necessary to connect

a speaker during this process.

1) Turn all controls full counter clockwise.

2) Turn the power on and allow 5 minutes for warm up.

3) Place the standby switch in the "on" position and allow another 5 minutes for the

tubes to stabilize.

4) You are now ready to measure. Set your voltmeter to the 200 millivolt scale. Insert the

black test probe into the "common" test point. Insert the red test probe into the #1 test point.

You should now see a reading within the range shown in the chart below.

While leaving the black probe connected, move the red probe to each of the four test points and

write down the voltage readings at each. You have now measured and documented the actual

current that is flowing through each of the four power tubes.

The readings should be within 5 millivolts of each other. If not, the tubes are not closely matched.

Now connect you meter to the rest point with the highest reading.

Turn the bias adjust with a small screw driver until the reading is within the value on the chart.

Tube Type

Min Value

Max Value

EL34

28mV

40mV

E34Ls

30mV

45mV

6L6

25mV

35mV

5881

25mV

35mV

KT66

25mV

35mV

6550

30mV

45mV

Note: 6V6 type is not safe to use due to the high (500 volts) plate voltage.