1.

Open the bag(s) of vermiculite and fill the entire burner pan
until the burner tube is completely covered (see Figure 21).

2.

Smooth the pan material just even with edges of the burner pan.

3.

Remove the ember material from the bag and flatten small
amounts into quarter size pieces and lay on top of the surface
of the pan material (see Figure 22).

4.

Place just enough to cover the entire surface and leave about a
1/2 inch gap under the lower grate members to allow air to
flow (see Figure 23).

INSTALLATION

Continued

DESA recommends that a black iron gas line be routed from the gas
source, through a sediment trap (shown in Figure 19), and into the
appliance, Once connected through the appliance, a flexible gas line
may be used for ease of installation to gas control valve (see Figure 20).

Before connecting the black iron gas line to the inside of the appliance
a sediment trap must be included outside the appliance between the gas
line and the gas shutoff valve. It must extend down three (3) inches
beyond the center of the pipe. Prepare incoming black iron gas line with
teflon tape or pipe joint compound (Check with local building codes).

Figure 20 - Connecting Flexible Gas Line to Millivolt Valve

WARNING: All gas piping and connections must

be tested for leaks after the installation is completed.

After ensuring that the gas valve is on, apply a
noncorrosive leak detection solution to all connec-
tions and joints. If bubbles appear, leaks can be
detected and corrected.

Do not use an open flame for leak testing and do not
operate any appliance if a leak is detected.

Complete your gas installation by connecting incoming gas line
with flexible gas line. Secure tightly with wrench but DO NOT
OVERTIGHTEN.

CAUTION: Compounds used on threaded joints

of gas piping shall be resistant to the action of
Liquefied Petroleum (LP or propane), and should be
applied lightly to ensure excess sealant does not
enter the gas line.

3" Min.

(76mm)

Side W

all

Of Appliance

Incoming 1/2" Gas Line
Permitted by Local Codes

Sediment Trap
(Not Supplied)

Figure 19 - Sediment Trap

Gas Shutoff
Valve

Flexible Gas Line
Do NOT Kink

1/2" NPT
Incoming
Gas Line

Note:
1) Wire Connections
Not Shown for Clarity
2) * 1/8" NPT Plugged
Tapping

Red Surface Indicates For
Propane/LP Use Only

Pilot Adj

Inlet
Pressure
Tap

Outlet
Pressure
Tap

Figure 21 - Fill Entire Burner Pan with Vermiculite (P325/VP325
Models Shown)

Figure 22 - Ember Material on Surface of Pan Material
(Vermiculite) (P325/VP325 Models Shown)

0.5"

0.5"

Figure 23 - Pan and Ember Material Clearances (P325/VP325
Models Shown)

Vermiculite
(Pan Material)

Burner Pan

Grate

Ember
Material

Burner Pan

Vermiculite
(Pan Material)

Grate

Grate

Burner Pan

Pan and Ember
Material

INSTALLATION

Gas Line Hook-Up (Cont.)
Ember and Pan Material Placement

Advertising