CLEARANCES

Minimum clearances to combustibles are:
• Top of Spacers ........................................................... 0" min.
• Back and Sides of Outer Surround ............................ 0" min.
• Drywall to Sides of Front Face (Nailing Flanges) ... 0" min.
• “B” Vent Surfaces ..................................................... 1" min.
• Ceiling to Opening .................................................. 42" min.
• Floor .......................................................................... 0" min.
• Perpendicular Wall ............................................ See Figure 6

CAUTION: Do not block required air spaces with

insulation or any other material. Do not obstruct effective
opening of appliance with any type of facing material.

PRE-INSTALLATION
PREPARATION

Figure 3 - Minimum Clearances (Top View)

Figure 4 - Minimum Clearances (Front View)

*

*

*

*

42" (1067mm)
Min. Clearance
from Opening to
Ceiling

0" Clearance

Ceiling

1" (25mm) Min.
Clearance to
"B" Vent’s Outer Pipe

Required Air
Spaces are
Indicated with
an "*". Do Not
Pack with
Insulation or Any
Other Material

DO NOT BLOCK

OR OBSTRUCT

OPENINGS

0" Clearance
to Wood or
Noncombustible
Flooring

MANTEL CLEARANCES AND WALL DETAILS

A combustible mantle shelf maybe installed a maximum 12"
(229mm) from the wall. Figures 5 and 6 show the minimum
allowable distances from various combustible mantle components
in relation to the fireplace opening.

Spacer

3" (76mm)

1

1

/

2

"

(38mm) Max.

8"

6" (152mm)

13"

12"

(229mm)

Combustible
Materials

Header

Figure 5 - Mantel Clearances - Side View (Cross Section)

1

1

/

2

" (38mm)

Max.

3" (76mm)
Max.

6" (152mm)
Max.

9"

12"

Outer Surround

Combustible
Material May
Be Used

TOP VIEW

SAFE
ZONE

Perpendicular
Wall

Figure 6 - Side Clearances - Top View (Cross Section)

PRE-INSTALLATION PREPARATION

Clearances
Mantel Clearances and Wall Details

0"

0" Clearance

Nailing
Flange

Front Face

Left Side
Surround

Back

Drywall

2 x 4 Stud