Fluke 789 User Manual

Page 53

Advertising
background image

ProcessMeter™

Specifications

45

General Specifications

Maximum voltage applied between
any jack and earth ground
.................................... 1000 V
Battery Type ........................................................... 1.5 V, 0-15 mA, AA, Alkaline
Storage temperature ............................................. -40

°

C to 60

°

C

Operating temperature .......................................... -20

°

C to 55

°

C

Operating altitude .................................................. 2000 meters maximum
Frequency Overload Protection

....................... 10

6

V Hz max

Temperature coefficient ........................................ 0.05 x specified accuracy per

°

C for temperatures <18

°

C or >28

°

C

0.1 x specified accuracy per

°

C for temperatures <18

°

C or >28

°

C

Relative humidity ................................................... 95 % up to 30

°

C, 75 % up to 40

°

C, 45 % up to 50

°

C, and 35 % up to 55

°

C

Vibration ................................................................. Random 2g, 5 to 500 Hz
Shock ...................................................................... 1 meter drop test
Power requirements .............................................. Four AA batteries (alkaline recommended)
Size ......................................................................... 10.0 cm X 20.3 cm X 5.0 cm (3.94 in X 8.00 in X 1.97 in)
Weight .................................................................... 610 g (1.6 lb)
Safety ...................................................................... IEC 61010-1: 600 V CAT IV / 1000 V CAT III, Pollution Degree 2
Electromagnetic Environment .............................. IEC 61326-1: Portable
Electromagnetic Compatibility ............................. Accuracy for all ProcessMeter functions is not specified in RF field > 3V/m

Applies to use in Korea only ................................ Class A Equipment (Industrial Broadcasting & Communication Equipment

[1]

[1] This product meets requirements for industrial (Class A) electromagnetic wave equipment and the seller or user should take notice of

it. This equipment is intended for use in business environments and not to be used in homes.