Nexen BD 933507 User Manual

Page 14

Advertising
background image

14

FORM NO. L-20063-AD-0314

This mode combines the Normal Service Mode and the
Normal Spring Engaged Mode. When engaged, air pressure
plumbed into the "Air-Engaged Port" adds to the actuation
force produced by the springs resulting in higher torque and
substantially reduces the life of the brake. Operating in this
manner induces loads that exceed normal design parameters
for the brake, care should be taken when operating with
this configuration.

(Not applicable for the 60 PSI canister)

AIR OPERATED—SPRING ENGAGED MODE

Connect to "Air-Engaged Port"

Brake is cycled with Air-Engaged Mode

Connected to "Spring

Engaged Port"

Quick Exhaust

Power source

wired to "Power

On" circuit.

Regulator

Figure 14

Lubricator

Regulator

Filter

Air Supply

Set at minimum Hold-Off

pressure (75 psi [5.17

bar])

3-Way

Manual

Valve

Power

Source

"ON"

75 psi [5.17 bar] air holds

spring in the disengaged

position. Spring engages

brake in the event of a

power loss.

Air-Engaged Port

Service

Service

Plug

Spring-Engaged Port

o

BSolete

t

hree

-P

ort

a

ctuator

Spring Brake

Service

t

wo

-P

ort

a

ctuator

Spring Brake

Air-Engaged Port

Spring-Engaged Port

CAUTION

Do not plug both Service Ports.

Install a breather (such as a

muffler) to one of these two ports.

CAUTION

Do not plug Service Port. Install

a breather (such as a muffler) to

the port.

WARNING

Applying the Normal Service Mode and the

Spring Engaged Mode simultaneously is outside

the normal operating range of the BD Caliper

Brake. The loads produced in the Friction

Facings (Item 4), Bearings (Item 14 and 15),

and the machine shaft are up to twice the normal

design loads.