Nexen RSD100 964520 User Manual

Page 11

Advertising
background image

11

FORM NO. L-21107-H-0108

m

inimum

c

OnnectiOnS

n

eceSSARy

F

OR

p

neumAtic

B

RAke

OR

c

lutch

A

pplicAtiOn

:

The RSD100 must have at least the following

connected to it for a pneumatic brake or clutch

application: a 24 VDC Power Supply, Dancer Arm

Position Sensor, Current- or Voltage-to-Pressure

Transducer, and a dry circuit contact or switch (Refer to

Figure 4).
 VDC Power Supply: Provides the power for

operation (Refer to SPECIFICATIONS for details).
Dancer arm Position Sensor: Provides an analog

signal that tracks dancer arm movement.
Current- or Voltage-to-Pressure Transducer: (ex.

Nexen’s EN50 or EN40) Converts the appropriate

control output (i.e. 4-20 mA or 0-10 VDC) into air

pressure for use with a pneumatic brake or clutch.
Machine State Signal: Provides a machine state signal

(ie: start, stop) to the RSD100.

Figure 

RED

BLACK

ORANGE

YELLOW

24VDC

Power Supply

+

_

COM

Rx

Tx

Users Access

to RS232

Connections

Auxiliary RS232

Communications Connection

(For set-up only).

RSD100

User's PLC

or

Computer

Gnd
Rx
Tx

7
3
2

Gnd

Rx

Tx

signal

signal pin

25 Pin Connectors

RSD100

User's PLC

or

Computer

Gnd
Rx
Tx

5
2
3

Gnd

Rx

Tx

signal

signal pin

9 Pin Connectors

m

inimum

c

OnnectiOnS

n

eceSSARy

F

OR

m

OtOR

D

Rive

A

pplicAtiOn

:

The RSD100 must have at least the following connected

to it for a motor drive applications: a 24 VDC Power

Supply, Dancer Arm Position Sensor, optional second

power supply, and a dry circuit contact or switch (Refer

to Figure 4).
 VDC Power Supply: Provides the power for operation

(Refer SPECIFICATIONS for details).
Dancer arm Position Sensor: Provides an analog signal

that tracks dancer arm movement.
Optional Power Supply: Used when isolated inputs

or output is required. Most commonly used to prevent

the mixing of power supply commons together when

connecting the analog output to a motor drive (Refer to

SPECIFICATIONS for details).
Machine State Signal: Provides a machine state signal

(ie: start, stop) to the RSD100.

RS Connections

Advertising
This manual is related to the following products: