Nexen RSD100 964520 User Manual

Page 19

Advertising
background image

19

FORM NO. L-21107-H-0108

6.0B D

iAmeteR

B

ASeD

A

DAptAtiOn

(DBA) S

ettingS

O

veRview

If a diameter sensor is installed and Diameter Based Adaptation (DBA) has been selected, then the diameter sensor

must be calibrated. Select the “Sensor Configuration” icon on the tool bar and then select Roll Diameter.

Figure 1

CaLIbRaTe The DIaMeTeR SeNSOR aS FOLLOWS:

c

ORe

D

iAmeteR

Measure the empty core diameter and enter this value in the CORE DIAMETER field.

F

ull

R

Oll

D

iAmeteR

Measure a full roll diameter and enter this value in the FULL ROLL DIAMETER field.

A dialog box will now appear prompting you to place an empty core on the shaft. Press OK when the core is being

measured by the diameter sensor. Next you will be prompted to place a full roll of maximum size on the machine.

Once the diameter sensor is measuring the full roll press “OK”. This completes the Roll Diameter Calibration. The roll

diameter can be monitored on the Diagnostics screen (Refer to Figure 18).

Advertising