Nexen RSD100 964520 User Manual

Page 12

Advertising
background image

FORM NO. L-21107-H-0108

1

1.5 RDS100p p

neumAtic

c

OnnectiOnS

Nexen developed the RSD100P for applications that would benefit from tension setpoint compensation (as

determined by the RSD100 Applications Chart). The RSD100P features an integral pressure sensor that connects

to the air supply pressure of the dancer arm loading cylinder. As the tension setpoint changes via the air pressure of

the loading cylinder, the RSD100P measures this change and adjusts its performance accordingly. The RSD100P

pressure sensor’s calibration procedure is listed in the Tension Compensation portion of Section 5.

RSD100P

Brake,
Clutch,
or Drive

Control
Output
Signal

Pneumatic
Loading
Cylinder

User Supplied
Air Pressure

Current or Voltage-to-Pressure Transducer

Tension
Setting Air
Pressure
Regulator

Figure 

1.4 R

Oll

D

iAmeteR

S

enSOR

An Ultrasonic Sensor can measure the change in roll radius

by bouncing sound waves off the material, enabling the

RSD100 to calculate roll diameter. For calibrations to be

accurate, the sensor must be installed perpendicular to

the axis of the wind or unwind shaft. Also, the Ultrasonic

Sensor must be mounted at least four inches [100 mm]

away from the maximum diameter roll.
adjustment of the Ultrasonic Sensor
Nexen’s Ultrasonic Sensor is factory adjusted for a 4 to 40

inch range and typically does not require re-adjustment prior

to use. If a shorter range is desired, then re-adjustment may

be performed by connecting a voltmeter to the sensor’s

output and turning P1 for the near point adjustment and P2

for the far point adjustment. (See figure 6) Adjust P1 and

P2 until the output voltage covers as much of the 0 to 10

VDC range as possible over the desired distance.

NOTe: The indicator on the end of the Ultrasonic

Sensor provides an indication of signal strength. The

indicator will light GReeN when the target is out of

range, and it fades to ReD as a target moves into

range, depending on how much reflected signal it re-

ceives from the target.
An Ultrasonic Sensor (See Figure 6) must be calibrated

to measure a minimum core diameter and a maximum roll

diameter that will be placed on the machine. Refer to the

6.0B Diameter Based Adaptation Settings section for a

description of this procedure.

Figure  - Ultrasonic Sensor

aDJUSTING

SCReWS

Ultrasonic Sensor

4" [100mm]

Minimum

40" [1,000mm]

Maximum

Green-Red

Indicator

P2

P1

(Near Point
Adjustment)

(Far Point
Adjustment)

NOTe: Factory attached fitting

accommodates 0. inch tubing.

a fitting for  mm tubing is also

included with the RSD100P.

Advertising