Calibration and adjustment, Limit switch adjustment, Ae120 calibration – Nexen Size 18 964102 User Manual

Page 4

Advertising
background image

4

FORM NO. L-20245-C-1099

CALIBRATION AND ADJUSTMENT

MODEL
AE120

MAN

CENTER

AUTO

AUTO

POWER

ON

LEFT

CPC

RIGHT

MAN

FIGURE 4

Remove

Screw

Error Indicator Array

Auto

Indicator

End of

Travel LED

Remove

Screw

Mode

Switch

Photo Head

Selector

Power

Switch

Fine

Adjustment

Control

Manual

Push

Buttons

LAMP

PH B1

GAIN 1

PH B2

GAIN 2

OUTPUT

F. ADJ

C. ZERO C. GAIN

Strain Relief

Clamps

NOR/REV

Switch for

Center

Operation

NOR/REV

Switch for

Auto

Operation

LAMP PHB1 GAIN 1 PHB2 GAIN 2 OUTPUT F. ADJ. C.ZERO C. GAIN

Terminal

Block

NOR/REV

Switch for

Manual

Operation

FIGURE 5

LIMIT SWITCH ADJUSTMENT

CAUTION

The Limit Switches have been set by Nexen for
maximum travel. If travel limitation is necessary, refer
to MAINTENANCE (Page 7) for Limit Switch Adjustment.

AE120 CALIBRATION

1.

Remove the two Screws located on the front panel of the
AE120 (See Figure 4).

2.

Slide the AE120 chassis out of the housing to allow
access to the Terminal Block (See Figure 5).

Advertising