Run the Preloaded Diagnostic Tests
Stratix GX HM-Zd SPI-4.2 Loopback
Figure 4–5. Install the HM-Zd SPI-4.2 Loopback Cards
4.
Supply power to the board.
5.
Confirm that the Stratix GX device has finished configuration (the
GX_CONF_DONE (D7) LED illuminates).
Run the Stratix GX HM-Zd SPI-4.2 Loopback Test
Perform the following steps to run the test.
1.
Setthe Stratix GX dipswitch 5 to 1 (up position).
2.
Press the reset pushbutton switch (GX_CLR).
3.
Press the start pushbutton switch (Stratix_GX_PB_0). Several LEDs
illuminate.
●
LED0 is the high-speed data match LED. If it illuminates, the test
is successful.
●
LED1 indicates that the GX device has received the data.