ABUS Technologies DP Series Smart Pressure Transmitter User Manual

Page 7

Advertising
background image

ABUS TECHNOLOGIES INC.

M94

7

Mounting Orientation Effect:

Zero drifts no more than 0.24kPa. No effect for movement

parallel to diaphragm. The error could be resolved by quick Zero

reset pushbutton on the instrument.

Power Voltage:

12V ~ 45V DC

Intrinsically safe/explosion-proof products with max 30 VDC

should be powered by safe Barrier

Parameters for intrinsically safety: U

0

≤ 28V DC,

type outsourcing safe barrier

I

0

≤ 30mA

P

0

≤ 0.84W

Physical Parameters:

O Ring of Contacting Medium:

Viton / Glass Filled PTFE

Filling liquid:

Silicone Oil / Inert Gas

Bolt:

Cadmium plated carbon steel.

Outer shell or electronic circuit:

Low Cu Al.

O shaped seal ring:

Acrylotrile-butadiene rubber, fluorine rubber polyurethane.

NOTE: Please refer to Ordering Table for Flange connector, Exhaust/Vent valves and Isolation

Diaphragm Material options

Pressure Connection Part:

¼ - 18 NPT for joint thread in pressure room,

½ - 14 NPT for joint thread in pressure guiding joint.

Weight:

Basic Model, 2.4Kg

Operation Environment under Normal Conditions

Operation Temperature(Ambient): Smart Type:-20°C ~ +85°C.

Storage Temperature:

-40°C ~ +104°C

Humidity:

0 ~ 90%

Atmospheric Pressure:

86 ~ 106 kPa

Operation Environment Conditions for Explosion-Proof Product

Humidity:

-20°C ~ +40°C

Relative Humidity:

5% ~ 95%

Atmospheric Pressure:

86 ~ -106 kPa