Connecting to the analog input – Applied Motion Si2035 User Manual

Page 12

Advertising
background image

12

12

12

12

12

Si2035 Hardware Manual

Si2035 Hardware Manual

Si2035 Hardware Manual

Si2035 Hardware Manual

Si2035 Hardware Manual

Connecting to the Analog Input

The analog input can be used only in SCL mode. The analog input can be read back to the
“Host” using the “IA” immediate type and “RA” buffered type commands. Readings are in
Volts.

+5 volt DC is provided for powering potentiometers. A 1000 to 10000 ohm potentiometer is
recommended and should be connected as shown below.

A 0 to 5 volt analog signal may also be used. Usually this signal comes from a PLC, a PC
with data acquisition card or a motion controller. Connections are shown below.

The +5V terminal is an output. Do not connect it to a power supply.

Connecting an Analog Input to a

Potentiometer

0 - 5V

speed signal

signal return

Si2035

GND

AIN

15

17

1-10k

Ω

pot

cw

ccw

Si2035

GND

AIN

+5

14

15

17

Connecting an Analog Input to an

Active Signal