Connection examples: step & dir, Connection examples: en, 14 stm23r hardware manual – Applied Motion STM23R-2ND User Manual

Page 14

Advertising
background image

14

STM23R Hardware Manual

920-0056C

5/5/2015

Connecting to Indexer with Differential Outputs

(Many High Speed Indexers have Differential Outputs)

Connecting to Indexer with Sinking Outputs

STM23R

+V OUT

DIR+

DIR

DIR-

STEP+

STEP

STEP-

Indexer

with

Sinking

Outputs

Connection Examples: STEP & DIR

Connecting to indexer with Sourcing Outputs

STM23R

COM

DIR-

DIR

DIR+

STEP-

STEP

STEP+

Indexer

with

Sourcing

Outputs

Connecting an Input to a Switch or Relay

STM23R

Switch or Relay

(closed = logic Low)

EN-

EN+

5-24

VDC

Power

Supply

-

+

Connection Examples: EN

STM23R

DIR+

DIR+

DIR-

DIR-

STEP+

STEP-

STEP+

STEP-

Indexer

with

Differential

Outputs

Advertising