Connecting the power supply, 7stm23r hardware manual, Choosing a power supply – Applied Motion STM23R-2ND User Manual

Page 7: Regen led

Advertising
background image

7

STM23R Hardware Manual

920-0056C

5/5/2015

Connecting the Power Supply

If you need information about choosing a power supply, please read the sec-

tion

Choosing a Power Supply

.

• Connect the power supply “+” terminal to the connector terminal labeled

“V+”.

• Connect power supply “-” to the connector terminal labeled “V-”.

• Use 18-20 gauge stranded wire.

The STM23R contains an internal fuse that connects to the power supply +

terminal. This fuse is not user replaceable. If you want to install a user service-

able fuse in your system install a fast acting 4 amp fuse in line with the + power supply lead.

Be careful not to reverse the wires. Reverse connection will destroy your drive, void your

warranty and generally wreck your day.

If you plan to use a regulated power supply you may encounter a problem with regeneration. If you rapidly

decelerate a load from a high speed, much of the kinetic energy of that load is transferred back to the power

supply. This can trip the overvoltage protection of a switching power supply, causing it to shut down. We offer

the RC-050 “regeneration clamp” to solve this problem. If in doubt, buy an RC-050 for your first installation. If

the “regen” LED on the RC-050 never flashes, you don’t need the clamp.

!

RC-050 Regen Clamp

regen LED

1

2

3

4

5

6

7

8

1

2

3

4

STEP+
STEP-
DIR+
DIR-
EN+
EN-
OUT+
OUT-
V-
V+

S/R

SETUP

Advertising
This manual is related to the following products: