3 en digital input – Applied Motion TXM24IP-1EG User Manual

Page 19

Advertising
background image

19

Rev. C

920-0089

TXM24 Ethernet Hardware Manual

3.4.3 EN Digital Input

While the STEP and DIR inputs are designed for high-speed digital input operation, the Enable

(EN) input is designed for low speed digital input operation between 5 and 24 volts.
Note: If current is flowing into or out of an input, the logic state of that input is low or closed. If no

current is flowing, or the input is not connected, the logic state is high or open.
The diagrams below show how to connect the EN input to various commonly used devices.

5 - 24

volt DC

Power

Supply

Connecting the Input to a Switch or Relay

EN+

EN-

+

-

TXM24

Switch or Relay

(closed = logic low)

5 - 24

volt DC

Power

Supply

Connecting an NPN type Proximity Sensor to an Input

(when prox sensor activates, input goes low)

EN+

EN-

+

-

+

NPN

Proximity

Sensor

-

output

TXM24

5 - 24

volt DC

Power

Supply

Connecting a PNP type Proximity Sensor to an Input

(when prox sensor activates, input goes high)

EN+

EN-

+

-

+

PNP

Proximity

Sensor

-

output

TXM24

Advertising