Trimpots

SPD

Used for adjusting the motor speed. Range is 0 to 4500 rpm and is active when pin 9 (SPST) is open.

ACC/DEC

Used for adjusting the motor acceleration/deceleration rate. Range is 0 to 3000 rev/sec

2

. Turn CW for shorter

ramp times, i.e. faster accel/decel rates.

Dip Switches

Inside the BD drive are four switches that can be used to select whether internal or external power is applied to

the optoisolator input circuits. There are four choices:

1. An external power supply +lead is applied to the INCOM terminal. Sinking signals must be used to control

the inputs. Set DIP switches 1 and 2 to OFF. There is full optical isolation under this condition.

2. Sourcing signals are applied to the inputs. INCOM is connected to the GND of the external power supply.

Also set DIP switches 1 and 2 to OFF. There is full optical isolation under this condition.

3. The internal 5V power supply is applied to INCOM. The inputs are driven with sinking signals connected

to pin 2, the GND pin. Set DIP switch 1 to ON and DIP switch 2 to OFF.

4. The internal GND is applied to INCOM. Sourcing signals powered by pin 12 (+5V) are used to drive the

inputs. Set DIP switches 1 and 2 to ON.

DIP SWITCHES